6 Setup

VEGASWING 66 • - Relay

44950-EN-130805

The instrument monitors the vibrating frequency, electronics tempera-

ture and internal instrument functions.

Red LED lights = fault

Relay deenergizes

The signal lamp for indication of the switching condition of the relay.

With the mode setting (4), the switching condition and hence the

function of the signal lamp can be changed.

Yellow LED lights = relay energized

Green LED lights = operating voltage on

With the mode setting (min./max.) you can change the switching

condition of the relay. You can set the required mode according to the

"Function chart" (max. - max. detection or overflow protection, min. -

min. detection or dry run protection).

With this DIL switch (3) you can set the switching point to liquids

having a density between 0.5 and 0.7 g/cm³ (0.018 and 0.025 lbs/

in³). With the basic setting, liquids with a density of ≥ 0.7 g/cm³ (0.025

lbs/in³) can be detected. In liquids with lower density, you must set

the switch to ≥ 0.5 g/cm³ (0.018 lbs/in³). The specifications for the

position of the switching point relate to water - density value 1 g/cm³

(0.036 lbs/in³). In products with a different density, the switching point

will shift in the direction of the housing or tuning fork end depending

on the density and type of installation.
Note:

Keep in mind that foams with a density > 0.45 g/cm³ (0.016 lbs/in³)

are detected by the sensor. This can cause faulty switchings particu-

lary when used as dry run protection system.
Note:

In case of strong boiling or deployment processes as well as extreme

outgasing, the density of the gas/product mixture on the product

surface can be so low that it can be no longer detected by the sensor.

This can cause faulty switchings.

6.3 Function chart

The following chart provides an overview of the switching conditions

depending on the set mode and the level.

Level

Switching sta-

tus

Signal lamp -

green
Voltage supply

Signal lamp -

yellow
Switching sta-

tus

Signal lamp

- red
Fault message

Mode (max.)
Overflow pro-

tection

5

3

4

(8)

(6) (7)

Relay energized

Control lamp (1) - fault

indication (red)

Signal lamp (2) - Switch-

ing condition (yellow)

Signal lamp (3) - Operat-

ing condition (green)
Mode setting (4)

Sensitivity adjustment (5)