VEGA MINITRAC 31 Foundation Fieldbus User Manual

Page 45

Advertising
background image

45

6 Set up with the display and adjustment module

MINITRAC 31 • Foundation Fieldbus

41782-EN-131119

Default settings: Resetting of the parameter adjustment like under

"Basic settings". In addition, special parameters are reset to default

values. Order-specific settings are deleted.
Peak values of measured value: Resetting of the parameter adjust-

ments in the menu item "Setup" to the default values of the respective

instrument. Order-specific settings remain but are not taken over into

the current parameters.
Peak values of temperature: Resetting of the measured min. and

max. temperatures to the actual measured value.
The following table shows the default values of the instrument. The

values apply for the application "Level". First of all you have to select

the application.
Depending on the instrument version, not all menu items may be

available or they may be differently assigned:

Menu

Menu item

Default value

Setup

Measurement loop name

Sensor

Isotope

Cs-137

Application

Density

Background radiation

0 ct/s

Unit of the process value

g/cm

3

Temperature unit

° C

Adjustment min. process

value

0.500 g/cm

3

Adjustment max. process

value

1.500 g/cm

3

Inner diameter

0.20 m

Linearization

90000 ct/s and 0.500 g/cm

3

Damping

60 s

Real value correction

0

Reference value - Relay

None

Block adjustment

Released

Display

Language

Selected language

Displayed value

Pulse rate

Display unit

ct/s

With this function

Load parameter adjustment data from the sensor into the display

and adjustment module

Write parameter adjustment data from the display and adjustment

module into the sensor

This parameter is described in the operating instructions manual

"Display and adjustment module".

Additional adjustments -

Copy instrument settings

Advertising