VEGA VEGABAR 82 4 … 20 mA - Operating Instructions User Manual

Page 58

Advertising
background image

58

10 Supplement

VEGABAR 82 • 4 … 20 mA

45027-EN-131010

Nominal range

Overload capacity, max.

pressure

Overload capacity, min. pres-

sure

0 … 5 psi

435 psi

0 psi

0 … 15 psi

510 psi

0 psi

0 … 30 psi

725 psi

0 psi

0 … 150 psi

1300 psi

0 psi

0 … 300 psi

1900 psi

0 psi

0 … 900 psi

2900 psi

0 psi

0 … +1450 psig
(only for measuring cell 17.5 mm)

2900 psig

0 psi

Output variable
Output signal

4 … 20 mA

Range of the output signal

3.55 … 22.0 mA (default setting)

Signal resolution

0.3 µA

Failure signal current output (adjustable) Last valid measured value, ≥ 21 mA, ≤ 3.6 mA
Max. output current

21.5 mA

Starting current

Ʋ up to 5 ms after switching on

≤ 3.6 mA

Ʋ 5 ms up to 5 s after switching on

≤ 10 mA

Ʋ 5 s up to 10 s after switching on

Adjusted failure current

Load

see load under Power supply

Damping (63 % of the input variable),

adjustable

0 … 999 s

Indication value - DIsplay and adjustment module

2)

Ʋ Displayed value 1

Pressure in bar/mbar

Ʋ Displayed value 2

Pressure in bar/mbar

Dynamic behaviour output
Run-up time approx.

10 s

Dynamic characteristics, depending on medium, temperature and, if applicable, chemical seal

2)

The indication values can be assigned individually