VEGA VEGAFLEX 83 4 … 20 mA_HART two-wire PFA insulated User Manual

Page 21

Advertising
background image

21

4 Mounting

VEGAFLEX 83 • 4 … 20 mA/HART two-wire

41834-EN-130612

In case of difficult installation conditions, for example in a socket, the

probe can be adapted respectively with a rod extension.
Let the probe length determine automatically by the instrument to

compensate the resulting running time changes.
You can find further information in the supplementary instructions of

the rod extension.

To compensate the normal bias voltage loss due to the seal materials,

you have to use also disc springs in addition to the flange screws for

fastening PTFE plated flanges.
The flange screws of VEGAFLEX 83 must always be tightened with

a torque of approx. 60 Nm (44 lbf ft) so that the PTFE washer seals

reliably.

Rod extension

Torque with PTFE plated

flanges

Advertising