VEGA VEGAFLEX 83 4 … 20 mA_HART two-wire Rod probe - Polished version With SIL qualification User Manual

Page 15

Advertising
background image

15

3 Product description

VEGAFLEX 83 • 4 … 20 mA/HART two-wire

44225-EN-130823

You can find further information in the operating instructions "Interface

adapter VEGACONNECT" (Document-ID 32628).

The VEGADIS 81 is an external display and adjustment unit for VEGA

plics

®

sensors.

For sensors with double chamber housing the interface adapter

"DISADAPT" is also required for VEGADIS 81.
You can find further information in the operating instructions "VE-

GADIS 81" (Document-ID 43814).

VEGADIS 62 is suitable for measured value indication and adjustment

of sensors with HART protocol. It is looped into the 4 … 20 mA/HART

signal cable.
You can find further information in the operating instructions "VE-

GADIS 62" (Document-ID 36469).

The protective cover protects the sensor housing against soiling and

intense heat from solar radiation.
You will find additional information in the supplementary instructions

manual "Protective cover" (Document-ID 34296).

Screwed flanges are available in different versions according to the

following standards: DIN 2501, EN 1092-1, BS 10, ANSI B 16.5,

JIS B 2210-1984, GOST 12821-80.
You can find additional information in the supplementary instructions

manual "Flanges according to DIN-EN-ASME-JIS" (Document-ID

31088).

The electronics module VEGAFLEX 80 series - SIL is a replacement

part for TDR sensors of the VEGAFLEX 80 series with SIL qualifica-

tion. Electronics modules with SIL qualification must only be replaced

by identical electronics modules.
You can find further information in the operating instructions manual

"Electronics module VEGAFLEX series 80".

The display and adjustment module can be optionally replaced by a

display and adjustment module with heating function.
You can use this display and adjustment module in an ambient tem-

perature range of -40 … +70 °C.
You can find further information in the operating instructions "Display

and adjustment module with heating" (Document-ID 31708).

If you mount the VEGAFLEX 83 in a bypass tube or standpipe, you

have to avoid contact to the bypass tube by using a spacer at the

probe end.
You can find additional information in the operating instructions

manual "Centering".

VEGADIS 81

VEGADIS 62

Protective cap

Flanges

Electronics module

Display and adjustment

module with heating

Spacer