4 Mounting

VEGASWING 66 • - Relay

43756-EN-130322

The vibrating level switch is a measuring instrument and must be

treated accordingly. Bending the vibrating element will destroy the

instrument.

Warning:

The housing must not be used to screw the instrument in! Applying

tightening force can damage internal parts of the housing.
Use the hexagon above the thread for screwing in.

4.2 Instructions for installation

The thread and the seal on the threaded version of VEGASWING

66 correspond to DIN 3852 part 1, screwed plug Form B (sealing by

metallic sealing edge).
Use screw-in openings or screw-in sleeves according to DIN 3852

part 2.
For mounting, proceed as follows:
1. Screw the VEGASWING 66 into the mounting boss up to the stop.

You can determine the later position already before welding.

2. Mark the position of the VEGASWING 66 on the mounting boss.
3. Mark the respective position of the mounting boss on the vessel

or pipeline.
Keep in mind that in case of lateral mounting, the marking of the

flat of VEGASWING 66 points upwards.
When mounting in pipelines, make sure that the surfaces of the

tuning fork are parallel to the direction of flow.

4. Remove the VEGASWING 66 from the mounting boss before

welding.

5. Weld the mounting boss according to your marking.

In case of horizontal mounting in adhesive and viscous products,

the surfaces of the tuning fork should be vertical in order to reduce

buildup on the tuning fork. On the screwed version you will find a

marking on the hexagon. With this, you can check the position of the

tuning fork when screwing it in.
In the case of flange versions, the fork is aligned with the flange holes.
When used in adhesive and viscous products, the tuning fork should

protrude into the vessel to avoid buildup. For that reason, sockets

for flanges and mounting bosses should be avoided when mounting

horizontally.

The process fitting must be sealed if there is gauge or low pressure in

the vessel. Before use, check if the seal material is resistant against

the measured product and the process temperature.
The max. permissible pressure is specified in chapter "Technical

data" or on the type label of the sensor.
Note:

Seal for instruments with process fitting thread