VEGA VEGASWING 66 - Relay User Manual

Page 31

Advertising
background image

31

9 Supplement

VEGASWING 66 • - Relay

43756-EN-130322

450 °C

(842 °F)

-196 °C

(-321 °F)

-40 °C

(-40 °F)

0 °C

(32 °F)

50 °C

(122 °F)

80 °C

(176 °F)

-20 °C

(-4 °F)

250 °C

(482 °F)

-110 °C

(-166 °F)

1

2

Fig. 47: Ambient temperature - Process temperature
1 Process temperature in °C (°F)

2 Ambient temperature in °C (°F)

Viscosity - dynamic

0.1 … 1000 mPa s (requirement: with density 1)

Flow velocity

max. 6 m/s (with a viscosity of 1000 mPa s)

Density

0.7 … 2.5 g/cm³ (0.025 … 0.09 lbs/in³); 0.47 … 2.5 g/

cm³ (0.0163 … 0.09 lbs/in³) by switching over

Electromechanical data
Cable entry/plug (dependent on the version)

Ʋ Single chamber housing

– 1 x cable entry M20 x 1.5 (use seal according to the

cable diameter), 1 x blind plug M20 x 1.5; attached 1 x

cable entry M20 x 1.5

or:

– 1 x cable entry ½ NPT, 1 x blind plug ½ NPT, 1 x cable

entry ½ NPT

or:

– 1 x plug M12 x 1; 1 x blind plug M20 x 1.5

Spring-loaded terminals

for wire cross-section up to 1.5 mm² (AWG 16)

Adjustment elements
Mode switch

Ʋ Max.

Max. detection or overflow/overfill protection

Ʋ Min.

Min. detection or dry run protection

Sensitivity switch

Ʋ ≥ 0.5

0.47 … 2.5 g/cm³ (0.0163 … 0.9 oz/in³)

Ʋ ≥ 0.7

0.7 … 2.5 g/cm³ (0.025 … 0.9 oz/in³)

Voltage supply
Operating voltage

20 … 253 V AC, 50/60 Hz, 20 … 72 V DC

Power consumption

1 … 8 VA (AC), approximately 1.5 W (DC)

Electrical protective measures
Protection rating

IP 66/IP 67

Overvoltage category

III

Advertising