VEGA VEGAFLEX 86 4 … 20 mA_HART - four-wire User Manual

Page 72

Advertising
background image

72

11 Supplement

VEGAFLEX 86 • 4 … 20 mA/HART - four-wire

41845-EN-130314

Ʋ Cable: ø 2 mm (0.079 in)

approx. 16 g/m (0.17 oz/ft)

Ʋ Cable: ø 4 mm (0.157 in)

approx. 60 g/m (0.65 oz/ft)

Ʋ Gravity weight for cable ø 2 mm

(0.079 in)

100 g (3.22 oz)

Ʋ Gravity weight for cable ø 4 mm

(0.157 in)

200 g (6.43 oz)

Ʋ Centering weight ø 40 mm (1.575 in) 180 g (5.79 oz)

Ʋ Centering weight ø 45 mm (1.772 in) 250 g (8.04 oz)

Ʋ Centering weight ø 75 mm (2.953 in) 825 g (26.52 oz)

Ʋ Centering weight (ø 95 mm (3.74 in)

1050 g (33.76 oz)

Probe length L (from seal surface)

Ʋ Rod: ø 16 mm (0.63 in)

up to 6 m (19.69 ft)

Ʋ Trimming accuracy - rod

±1 mm

Ʋ Cable: ø 2 mm (0.079 in)

up to 75 m (246.1 ft)

Ʋ Cable: ø 4 mm (0.157 in)

up to 75 m (246.1 ft)

Ʋ Trimming accuracy - cable

±0.05 %

Lateral load

Ʋ Rod: ø 16 mm (0.63 in)

30 Nm (22 lbf ft)

Max. tensile load

Ʋ Cable: ø 2 mm (0.079 in)

1.5 KN (337 lbf)

Ʋ Cable: ø 4 mm (0.157 in)

2.5 KN (562 lbf)

Thread in gravity weight, e.g. for eye-bolt

(cable version)

M 8

Torque for exchangeable cable or rod probe (in the process fitting)

Ʋ Cable: ø 2 mm (0.079 in)

20 Nm (14.75 lbf ft)

Ʋ Cable: ø 4 mm (0.157 in)

20 Nm (14.75 lbf ft)

Ʋ Rod: ø 16 mm (0.63 in)

20 Nm (14.75 lbf ft)

Torque for NPT cable glands and Conduit tubes

Ʋ Plastic housing

max. 10 Nm (7.376 lbf ft)

Ʋ Aluminium/Stainless steel housing

max. 50 Nm (36.88 lbf ft)

Input variable
Measured variable

Level of liquids

Min. dielectric constant of the medium

Ʋ Cable probes

ε

r

≥ 1.6

Ʋ Rod probes

ε

r

≥ 1.6

Advertising