0
2 mm
(0.079")
-2 mm
(-0.079")
15 mm
(0.591")
10 mm
(0.394")
0,08 m
(3.15")
0,3 m
(11.811")
0,1m
(3.94")
L
1
Fig. 41: Deviation VEGAFLEX 86 in cable version in water
1 Dead band - no measurement possible in this area
L Probe length
L
0
-15 mm
(-0.591")
2 mm
(0.079")
-2 mm
(-0.079")
25 mm
(0.984")
0,2 m
(7.874")
0,15 m
(5.906")
0,08 m
(3.15")
0,1 m
(3.937")
1
1
Fig. 42: Deviation VEGAFLEX 86 in cable version 2 mm (0.079 in), in oil
1 Dead band - no measurement possible in this area