4 Mounting

VEGABAR 87 • HART and accumulator pack

45045-EN-131107

1

2

3

6

6

6

6

6

5

4

Fig. 5: Position of the filter element - non-Ex, Ex-ia and Ex-d-ia version
1 Single chamber housing plastic, stainless steel (precision casting)

2 Single chamber housing Aluminium

3 Single chamber housing, stainless steel electropolished

4 Double chamber housing plastic

5 Double chamber housing Aluminium

6 Filter element

With the following instruments a blind plug is installed instead of the

filter element:

Instruments in protection IP 66/IP 68 (1 bar) - ventilation via capil-

laries in fix connected cable

Instruments with absolut pressure

4.3 Level measurement

Keep the following in mind when setting up the measuring system:

Do not mount the instrument close to the filling stream or emptying

area

Mount the instrument so that it is protected against pressure

shocks from the stirrer

Measurement setup

Advertising