CONFIGURATION

73

6.21. Expansion Port Configuration

The expansion port configuration can be called up by airbrush option External Port

in menu. Inside the window can be defined Baudrate, number of Data bits, Parity, number
of Stop bits, Protocol and Mode. Split timeout is for messages.

In mode TCP server it is necessary to enter the TCP port, on which the router will

listen to incoming requests about TCP connection. In mode TCP client it is necessary
to enter the Server address and final TCP port.

At Check TCP connection it activates verification of coupled TCP connection. Inside

the window can be defined time, after which it will carry out verification of the connection
(Keepalive Time), waiting time on answer (Keepalive Interval) and number of tests
(Keepalive Probes).

In case of M-BUS expansion board installed and when chosen protocol is not M-BUS

or M-BUS TCP then sent data will be returned back to the device! If e.g. LINE protocol is set-
up on this port, then data will return back to the source.

The changes in settings will apply after pressing the Apply button.

Example of external port configuration:

192.168.1.100

ppp0 10.0.0.1
192.168.1.1

ppp0 10.0.0.2

Settings in application on PC:

TCP connection on 10.0.0.2:2000

Settings in the router

Mode:

TCP server

Server Address: -
TCP Port:

2000

ETH

RS232

PC

PLC

Default Gateway 192.168.1.1



























































LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de