VEGA VEGAPULS 61 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA__HART four-wire User Manual

Page 51

Advertising
background image

M

in. distance from antenna end

50

mm (1.969 in)

4)

R

ecommended measuring range, encapsu-

lated antenna system

up to 10 m (32.81 ft)

R

ecommended measuring range plastic horn

antenna

up to 20 m (65.62 ft)

Reference conditions to measuring accuracy (similar to DIN EN 60770-1)

R

eference conditions according to DIN EN 61298-1

-

T

emperature

+

18 … +30 °C (+64 … +86 °F)

-

R

elative humidity

45 … 75 %

-

A

ir pressure

860 … 1060

mbar/86 … 106 kPa (12.5 … 15.4 psig)

O

ther reference conditions

-

R

eflector

ideal reflector, e.g. metal plate 2 x 2 m

-

F

alse reflections

L

argest false echo 20 dB smaller than the useful

echo

Characteristics and performance data

F

requency

K-

band (26 GHz technology)

M

eas. interval approx.

1

s

B

eam angle -3 dB

5)

-

E

ncapsulated antenna system

22°

-

P

lastic horn antenna

10°

S

tep response or adjustment time

6)

<

1

s (dependent on the parameter settings)

M

ax. level change

A

djustable up to 1 m/min. (dependent on the

parameter settings)

M

ax. emitted HF power of the antenna system

-

P

ulse peak power

<

2

mW

-

P

ulse duration

<

2

ns

-

A

verage power

<

5 µW

-

A

verage power with 1 m distance

<

200

nW/cm

2

M

ax. emitted HF power of the antenna system - Version with increased sensitivity

-

P

ulse peak power

<

10

mW

-

P

ulse duration

<

2

ns

-

A

verage power

<

25 µW

-

A

verage power with 1 m distance

<

1 µW/

cm

2

4)

I

n products with low dielectric value up to 50 cm (19.69 in).

5)

C

orresponds to the range with 50 % of the emitted power

6)

T

ime to output the correct level (with max. 10 % deviation) after a sudden

level change.

VEGAPULS

61 • 4 … 20

mA/HART four-wire

51

10 S

upplement

28439

-EN

-100426

Advertising