Rainbow Electronics T89C51RD2 User Manual

Page 63

Advertising
background image

63

Rev. F - 15 February, 2001

T89C51RD2

API call

Parameter

READ copy of the device
ID # 1

Input Parameters:
R0 = osc freq (integer Not required, left for Philips compatibility)
R1 = 00h
DPH = 00h
DPL = 01h (device ID # 1)
Return Parameter
ACC = value of byte read

READ copy of the device
ID # 2

Input Parameters:
R0 = osc freq (integer Not required, left for Philips compatibility)
R1 = 00h
DPH = 00h
DPL = 02h (device ID # 2)
Return Parameter
ACC = value of byte read

READ copy of the device
ID # 3

Input Parameters:
R0 = osc freq (integer Not required, left for Philips compatibility)
R1 = 00h
DPH = 00h
DPL = 03h (device ID # 2)
Return Parameter
ACC = value of byte read

READ SOFTWARE
SECURITY BITS

Input Parameters:
R0 = osc freq (integer Not required, left for Philips compatibility)
R1 = 07h
DPH = 00h
DPL = 00h (Software security bits)
Return Parameter
ACC = value of byte read

READ copy of the
HARDWARE SECURITY
BITS

Input Parameters:
R0 = osc freq (integer Not required, left for Philips compatibility)
R1 = 07h
DPH = 00h
DPL = 03h (Hardtware security bits)
Return Parameter
ACC = value of byte read

READ BOOT VECTOR

Input Parameters:
R0 = osc freq (integer Not required, left for Philips compatibility)
R1 = 07h
DPH = 00h
DPL = 02h (boot vector)
Return Parameter
ACC = value of byte read

READ BOOTLOADER
VERSION

Input Parameters:
R0 = osc freq (integer Not required, left for Philips compatibility)
R1 = 08h
Return Parameter
ACC = value of byte read

READ BOOT STATUS
BYTE

Input Parameters:
R0 = osc freq (integer Not required, left for Philips compatibility)
R1 = 07h
DPH = 00h
DPL = 01h (status byte)
Return Parameter
ACC = value of byte read

Table 33. API calls

Advertising