Resistor, the charger enters a temperature suspend – Rainbow Electronics MAX8903A User Manual

Page 18

Advertising
background image

MAX8903A

2A 1-Cell Li+ DC-DC Charger for USB*
and Adapter Power

18

______________________________________________________________________________________

charging resumes and the charge timer continues from
where it left off. Connecting THM to GND disables the
thermistor monitoring function. Table 4 lists the fault
temperature of different thermistors.

Since the thermistor monitoring circuit employs an
external bias resistor from THM to VL (R

TB

, Figure 7),

the thermistor is not limited only to 10k

Ω (at +25°C).

Any resistance thermistor can be used as long as the
value is equivalent to the thermistor’s +25°C resistance.
For example, with a 10k

Ω at +25°C thermistor, use

10k

Ω at R

TB

, and with a 100k

Ω at +25°C thermistor,

use 100k

Ω .

For a typical 10k

Ω (at +25°C) thermistor and a 10kΩ

R

TB

resistor, the charger enters a temperature suspend

FAULT

UOK AND/OR DOK = LOW
CHG = HIGH IMPEDANCE

FLT = LOW

I

CHG

= 0mA

PREQUALIFICATION

UOK AND/OR DOK = LOW

CHG = LOW

FLT = HIGH IMPEDANCE

0 < V

BAT

< 3V

I

CHG

≤ I

CHGMAX

/10

DONE

UOK AND/OR DOK = 0

CHG = HIGH IMPEDANCE

FLT = HIGH IMPEDANCE

4.1V < V

BAT

< 4.2V

I

CHG

= 0mA

FAST-CHARGE

UOK AND/OR DOK = LOW

CHG = LOW

FLT = HIGH IMPEDANCE

3V < V

BAT

< 4.2V

I

CHG

≤ I

CHGMAX

NOT READY

UOK AND DOK = HIGH IMPEDANCE

CHG = HIGH IMPEDANCE

FLT = HIGH IMPEDANCE

I

CHG

= 0mA

TIMER > t

PREQUAL

V

BATT

> 3.0V

RESET TIMER

V

BATT

< 2.82V

RESET TIMER = 0

I

CHG

< I

TERM

AND V

BAT

= 4.2V

AND THERMAL
OR INPUT LIMIT
NOT EXCEEDED;
RESET TIMER

I

CHG

> I

TERM

RESET TIMER

V

BAT

< 4.1V

RESET TIMER

TIMER > 15s

UOK AND/OR DOK = LOW
CEN = 0
RESET TIMER

CEN = HI OR
REMOVE AND RECONNECT
THE INPUT SOURCE(S)

ANY STATE

TOGGLE CEN OR

REMOVE AND RECONNECT

THE INPUT SOURCE(S)

TIMER > t

FSTCHG

(TIMER SLOWED BY 2x IF
I

CHG

< I

CHGMAX

/2, AND

PAUSED IF I

CHG

< I

CHGMAX

/5 WHILE V

BAT

< 4.2V)

TOP-OFF

UOK AND/OR DOK = LOW
CHG = HIGH IMPEDANCE

FLT = HIGH IMPEDANCE

VBAT = 4.2V

I

CHG

= I

TERM

TEMPERATURE SUSPEND

I

CHG

= 0mA

UOK OR DOK PREVIOUS STATE

CHG = HIGH IMPEDANCE

FLT = HIGH IMPEDANCE

ANY CHARGING

STATE

THM NOT OK
TIMER SUSPEND

THM OK

TIMER RESUME

V

BATT

< 2.8V

RESET TIMER

Figure 6. MAX8903A Charger State Flow Chart

Advertising