Table 6. Blink Phase 0 Registers

REGISTER DATA

REGISTER

R/

W

ADDRESS

CODE

(hex)

D7

D6

D5

D4

D3

D2

D1

D0

Write outputs O7–O0 phase 0

0

Read back outputs O7–O0 phase 0

1

0x02

OP7

OP6

OP5

OP4

OP3

OP2

OP1

OP0

Write outputs O15–O8 phase 0

0

Read back outputs O15–O8 phase 0

1

0x03

OP15

OP14

OP13

OP12

OP11

OP10

OP9

OP8

Table 7. Blink Phase 1 Registers

REGISTER DATA

REGISTER

R/

W

ADDRESS

CODE

(hex)

D7

D6

D5

D4

D3

D2

D1

D0

Write outputs O7–O0 phase 1

0

Read back outputs O7–O0 phase 1

1

0x0A

OP7

OP6

OP5

OP4

OP3

OP2

OP1

OP0

Write outputs O15–O8 phase 1

0

Read back outputs O15–O8 phase 1

1

0x0B

OP15

OP14

OP13

OP12

OP11

OP10

OP9

OP8

Table 8. PWM Application Scenarios

APPLICATION

RECOMMENDED CONFIGURATION

All outputs static without PWM

Set the master and global intensity register 0x0E to any value from 0x00 to 0x0F.
The global intensity G bit in the configuration register is don't care.
The output intensity registers 0x10 through 0x17 are don't care.

A mix of static and PWM outputs, with PWM
outputs using different PWM settings

Set the master and global intensity register 0x0E to any value from 0x10 to 0xFF.
Clear global intensity G bit to zero in the configuration register to disable global
intensity control.
For the static outputs, set the output intensity value to 0xF.
For the PWM outputs, set the output intensity value in the range 0x0 to 0xE.

A mix of static and PWM outputs, with PWM
outputs all using the same PWM setting

As above. Global intensity control cannot be used with a mix of static and PWM
outputs, so write the individual intensity registers with the same PWM value.

All outputs PWM using the same PWM
setting

Set the master and global intensity register 0x0E to any value from 0x10 to 0xFF.
Set global intensity G bit to 1 in the configuration register to enable global intensity
control.
The master and global intensity register 0x0E is the only intensity register used.
The output intensity registers 0x10 through 0x17 are don't care.