Rainbow Electronics MAX6964 User Manual

Page 9

Advertising
background image

If multiple data bytes are transmitted before a STOP con-
dition is detected, these bytes are generally stored in
subsequent MAX6964 internal registers because the
command byte address autoincrements (

Table 2

). A

diagram of a write to the output ports registers (blink
phase 0 registers or blink phase 1 registers) is given in

Figure 10

.

Message Format for Reading

The MAX6964 is read using the MAX6964’s internally
stored command byte as an address pointer the same
way the stored command byte is used as an address
pointer for a write. The pointer autoincrements after
each data byte is read using the same rules as for a
write (

Table 2

). Thus, a read is initiated by first configur-

MAX6964

17-Output LED Driver/GPO

with Intensity Control

_______________________________________________________________________________________

9

Figure 8. Command and Single Data Byte Received

S

A

A

A

P

0

SLAVE ADDRESS

COMMAND BYTE

DATA BYTE

1

BYTE

AUTOINCREMENT MEMORY ADDRESS

D15 D14 D13 D12 D11 D10

D9

D8

D1

D0

D3

D2

D5

D4

D7

D6

ACKNOWLEDGE FROM MAX

6964

ACKNOWLEDGE FROM MAX

6964

ACKNOWLEDGE FROM MAX

6964

HOW COMMAND BYTE AND DATA BYTE MAP INTO

MAX

6964

's REGISTERS

R/W

Figure 9. n Data Bytes Received

S

A

A

A

P

0

SLAVE ADDRESS

COMMAND BYTE

DATA BYTE

N

BYTE

AUTOINCREMENT MEMORY ADDRESS

D15 D14 D13 D12 D11 D10

D9

D8

D1

D0

D3

D2

D5

D4

D7

D6

ACKNOWLEDGE FROM MAX

6964

ACKNOWLEDGE FROM MAX

6964

ACKNOWLEDGE FROM MAX

6964

HOW COMMAND BYTE AND DATA BYTE MAP INTO

MAX

6964

's REGISTERS

R/W

Figure 7. Command Byte Received

S

A

A

P

0

SLAVE ADDRESS

COMMAND BYTE

ACKNOWLEDGE FROM MAX6964

D15

D14

D13

D12

D11

D10

D9

D8

COMMAND BYTE IS STORED ON RECEIPT OF

STOP CONDITION

ACKNOWLEDGE FROM MAX6964

R/W

Figure 10. Write Timing Diagram

SLAVE ADDRESS

1

2

3

4

5

6

7

8

9

S A6 A5 A4 A3 A2 A1 A0

0

A

0

0

0

0

0

0

0

COMMAND BYTE

1

A

A

A

P

START CONDITION

ACKNOWLEDGE FROM SLAVE

ACKNOWLEDGE FROM SLAVE

ACKNOWLEDGE FROM SLAVE

STOP

CONDITION

O7–O0

O15– O8

DATA1 VALID

DATA2 VALID

t

DV

t

DV

SCL

SDA

WRITE TO OUTPUT PORTS REGISTERS (BLINK PHASE 0 REGISTERS/BLINK PHASE 1 REGISTERS)

R/W

MSB

LSB

DATA1

MSB

LSB

DATA2

Advertising