Max6964, Output led driver/gpo with intensity control, Table 2. register address map – Rainbow Electronics MAX6964 User Manual

Page 8

Advertising
background image

MAX6964

during the high period of the clock pulse. When the
master is transmitting to the MAX6964, the device gen-
erates the acknowledge bit because the MAX6964 is
the recipient. When the MAX6964 is transmitting to the
master, the master generates the acknowledge bit
because the master is the recipient.

Slave Address

The MAX6964 has a 7-bit long slave address (

Figure 6

).

The eighth bit following the 7-bit slave address is the
R/W bit. The R/W bit is low for a write command, high
for a read command.

The second (A5), third (A4), fourth (A3), sixth (A1), and
last (A0) bits of the MAX6964 slave address are always
1, 0, 0, 0, and 0. Slave address bits A6 and A2 are
selected by the address input AD0. AD0 can be con-
nected to GND, V+, SDA, or SCL. The MAX6964 has

four possible slave addresses (

Table 1

), and therefore

a maximum of four MAX6964 devices can be controlled
independently from the same interface.

Message Format for Writing the MAX6964

A write to the MAX6964 comprises the transmission of
the MAX6964’s slave address with the R/W bit set to
zero, followed by at least 1 byte of information. The first
byte of information is the command byte. The command
byte determines which register of the MAX6964 is to be
written to by the next byte, if received (

Table 2

). If a

STOP condition is detected after the command byte is
received, then the MAX6964 takes no further action
beyond storing the command byte.

Any bytes received after the command byte are data
bytes. The first data byte goes into the internal register of
the MAX6964 selected by the command byte (

Figure 8

).

17-Output LED Driver/GPO
with Intensity Control

8

_______________________________________________________________________________________

Table 1. MAX6964 Address Map

DEVICE ADDRESS

PIN AD0

A6

A5

A4

A3

A2

A1

A0

SCL

1

1

0

0

0

0

0

SDA

1

1

0

0

1

0

0

GND

0

1

0

0

0

0

0

V+

0

1

0

0

1

0

0

Table 2. Register Address Map

REGISTER

ADDRESS CODE

(hex)

AUTOINCREMENT

ADDRESS

Blink phase 0 outputs O7–O0

0x02

0x03

Blink phase 0 outputs O15–O8

0x03

0x02

User RAM0

0x06

0x07

User RAM1

0x07

0x06

Blink phase 1 outputs O7–O0

0x0A

0x0B

Blink phase 1 outputs O15–O8

0x0B

0x0A

Master and global/O16 intensity

0x0E

Configuration

0x0F

Outputs intensity O1, O0

0x10

0x11

Outputs intensity O3, O2

0x11

0x12

Outputs intensity O5, O4

0x12

0x13

Outputs intensity O7, O6

0x13

0x14

Outputs intensity O9, O8

0x14

0x15

Outputs intensity O11, O10

0x15

0x16

Outputs intensity O13, O12

0x16

0x17

Outputs intensity O15, O14

0x17

0x10