3 specification of low voltage reset, 4 specification of brownout detector, 5 specification of power-on reset (5v) – Rainbow Electronics NUC120 User Manual

Page 63: Specification of low voltage reset, Specification of brownout detector, Specification of power-on reset (5v), Nuc120 series data sheet

Advertising
background image

NUC120 Series DATA SHEET

Publication Release Date: May 31, 2010

- 63 -

Revision V1.02

7.4.3

Specification of Low Voltage Reset

PARAMETER CONDITION

MIN.

TYP.

MAX.

UNIT

Operation voltage

-

1.7

-

5.5 V

Quiescent current

VDD5V=5.5V

-

-

5

uA

Temperature

-

-40 25 85 ℃

Temperature=25°

1.7 2.0 2.3 V

Temperature=-40° - 2.4 - V

Threshold voltage

Temperature=85° - 1.6 - V

Hysteresis

-

0

0

0

V

7.4.4

Specification of Brownout Detector

PARAMETER CONDITION

MIN.

TYP.

MAX.

UNIT

Operation voltage

-

2.5

-

5.5

V

Quiescent current

AVDD=5.5V

-

-

125

μA

Temperature

-

-40 25 85

BOV_VL[1:0]=11

4.4

4.5

4.6

V

BOV_VL [1:0]=10

3.7

3.8

3.9

V

BOV_VL [1:0]=01

2.6

2.7

2.8

V

Brown-out voltage

BOV_VL [1:0]=00

2.1

2.2

2.3

V

Hysteresis

-

30m

-

150m

V

7.4.5

Specification of Power-On Reset (5V)

PARAMETER CONDITION

MIN.

TYP.

MAX.

UNIT

Temperature -

-40

25

85

Reset voltage

V+

-

2

-

V

Quiescent current

Vin>reset voltage

-

1

-

nA

Advertising