5440A–IMAGE–10/05

[Preliminary] ATMOS -2M60/2M30

10A

1

RW

-

0

Current configuration restore from Eeprom

1 to 4: User settings

10B

1

WO

-

FPN coefficient save in dataflash

1 to 4 (1 allowed only for advanced user
mode)

10C

1

RW

-

1

FPN coefficient restore in dataflash

1 to 4

10D

1

WO

-

LUT coefficient save in dataflash

1 to 4 (1 allowed only for advanced user
mode)

10E

1

RW

-

1

LUT coefficient restore in dataflash

1 to 4

200

2

RW

RW

0

Calibration control

[0] = off-line calibration enabled

(0: disabled; 1: enabled)

202

2

RW

-

0

Processing control:

[0] = offset correction enable (0: disabled;
1: enabled)

[1] = gain correction enable (0: disabled;

1: enabled)

[2] = look-up table correction enable

(0: disabled; 1: enabled)[

[4:3] = fpn correction mode (00: disabled;
01: off-line fpn correction enabled; 11: on-
line fpn correction enabled)

204

2

RW

-

0

Mode control:

[1:0] = test pattern (00: disabled; 01: fixed
test pattern; 10: dynamic test pattern)

[3:2] = output format (00:12-bit; 01:10-bit;
10:8-bit)

[[7:5] = synchronization mode (000: Free-
run; 001: External triggered; 010: external
triggered without full reset; 011: integration
time controlled); others reserved

[8] = trigger source (0: Camera Link; 1:
external)

[9] = trigger polarity (0:positive edge; 1:
negative edge)

[10] = shutter polarity output (0: positive
edge; 1: negative edge)

206

1

WO

Software reset:

1 = camera reset

Table 6-6.

Internal Register Mapping (Continued)

Start Addr

(Hex)

Size (Dec)

End

Addr (Hex)

Access Type

Processing Internal Task

Factory

Settings

Description