Rainbow Electronics ATMOS™ 2M60 User Manual

Page 9

Advertising
background image

9

5440A–IMAGE–10/05

[Preliminary] ATMOS -2M60/2M30

• Readout of frame N. The readout data is forwarded to the Camera Link interface (FVAL

active) starting with the first line

• Readout of dummy frames (to prevent against large dark current integration) while the

camera waits for the next trigger event

The trigger delay is a few µs. The minimum pulse duration is 1 µs. The edge of trigger is pro-
grammable. The source of trigger is selectable between Camera Link CC1 signal and TTL_IO
trigger input. The period is defined by the programmable shutter time + readout time + wait.
Therefore the minimum period is reduced to 1 × readout time. As the integration time is not the
same for all lines (in the following timing diagram line n integration time is greater than line 1
integration time) this mode must be used with a pulsed light source or a shutter element. More-
over any residual light when shutter output signal is inhibited must be avoided. The exposure
time is defined by the shutter time and all the lines are exposed during the same time.

See register Aperture Shutter Time @ 246H Internal Register Mapping on

page 16

.

Figure 4-4.

Triggered Mode Without Full Reset Chronogram

Table 4-3.

Shutter Time Values at Triggered Mode without Full Reset

Label

Description

2M60

2M30

Tsh

Maximum shutter time (ms)

655

1310

T1

Step duration (µs)

10

20

Line1 Reset

Line 1

Integration

(Frame N)

Frame N

Readout

Line n

Integration

(Frame N)

Line n Reset

Line 1 Readout

and Reset

Trigger N Event

Trigger In

Programmable

Shutter Time

Shutter out

Trigger Delay

FVA

L

Line n Readout

and Reset

Advertising