4 triggered mode without full reset – Rainbow Electronics ATMOS™ 2M60 User Manual

Page 8

Advertising
background image

8

5440A–IMAGE–10/05

ATMOS -2M60/2M30 [Preliminary]

• Readout of frame N. The readout data is forwarded to the Camera Link interface (FVAL

active) starting with the first line

• Readout of dummy frames (to prevent against large dark current integration) while the

camera waits for the next trigger event

The trigger delay is a few µs. The minimum pulse duration is 1 µs. The edge of trigger is pro-
grammable. The source of trigger is selectable between Camera Link CC1 signal and TTL/IO
trigger input. The period is defined by readout time + programmable shutter time + readout time
+ wait. Therefore the minimum period is 2

×

readout time.

See register Aperture Shutter Time @ 246H, Internal Register Mapping on

page 16

.

Figure 4-3.

Triggered Mode Chronogram

4.1.4

Triggered Mode without Full Reset

Principle: An external trigger starts the snap and readout of a frame, without resetting the sen-
sor. The integration time is defined by readout time (+ programmable shutter time, when used).

The trigger event initiates the following sequence:

• Stop of readout frame in progress and reset of readout pointer to line 1

• Shutter output signal is activated during a time programmable within 0 to Tsh range by step

of T1

Table 4-2.

Shutter Time Values at Triggered Mode

Label

Description

2M60

2M30

Tsh

Maximum shutter time (ms)

655

1310

T1

Step duration (µs)

10

20

Line 1 reset

Line 1

Integration

(Frame N)

Frame N

Readout

Line n

Integration

(Frame N)

Line n Reset

Line 1 Readout

and Reset

Trigger N Event

Trigger In

Programmable

Shutter Time

Shutter out

Trigger Delay

FVAL

Line n Readout

and Reset

Advertising