December 4, 2001

In the event count or timer mode, the timer/event coun-
ter starts counting at the current contents in the
timer/event counter and ends at FFH (FFFFH). Once an
overflow occurs, the counter is reloaded from the
timer/event counter preload register, and generates an
interrupt request flag (T0F; bit 6 of INTC0, T1F; bit 4 of
INTC1).

In the pulse width measurement mode with the values of
the TON and TE bits equal to 1, after the TMR0 (TMR1)
has received a transient from low to high (or high to low

if the TE bit is

²0²), it will start counting until the TMR0

(TMR1) returns to the original level and resets the TON.
The measured result remains in the timer/event counter
even if the activated transient occurs again. In other
words, only 1-cycle measurement can be made until the
TON is set. The cycle measurement will re-function as
long as it receives further transient pulse. In this opera-
tion mode, the timer/event counter begins counting not
according to the logic level but to the transient edges. In
the case of counter overflows, the counter is reloaded
from the timer/event counter register and issues an in-
terrupt request, as in the other two modes, i.e., event
and timer modes.

To enable the counting operation, the Timer ON bit
(TON; bit 4 of TMR0C or TMR1C) should be set to 1. In
the pulse width measurement mode, the TON is auto-
matically cleared after the measurement cycle is com-
pleted. But in the other two modes, the TON can only be
reset by instructions. The overflow of the Timer/Event
Counter 0/1 is one of the wake-up sources and can also
be applied to a PFD (Programmable Frequency Divider)
output at PA3 by options. Only one PFD (PFD0 or
PFD1) can be applied to PA3 by options . No matter
what the operation mode is, writing a 0 to ET0I or ET1I
disables the related interrupt service. When the PFD

function is selected, executing

²CLR [PA].3² instruction

to enable PFD output and executing

²SET [PA].3²

instruction to disable PFD output.

In the case of timer/event counter OFF condition, writing
data to the timer/event counter preload register also re-
loads that data to the timer/event counter. But if the
timer/event counter is turn on, data written to the
timer/event counter is kept only in the timer/event coun-
ter preload register. The timer/event counter still contin-
ues its operation until an overflow occurs.

Label

(TMR0C)

Bits

Function

¾

0~2

Unused bit, read as

²0²

TE

3

Defines the TMR0 active edge of timer/event counter
(0=active on low to high; 1=active on high to low)

TON

4

Enable/disable timer counting
(0=disabled; 1=enabled)

TN2

5

2 to 1 multiplexer control inputs which selects the timer/event counter clock source
(0=RTC outputs; 1= system clock or system clock/4)

TN0
TN1

6
7

Defines the operating mode (TN1, TN0)
01= Event count mode (External clock)
10= Timer mode (Internal clock)
11= Pulse Width measurement mode (External clock)
00= Unused

TMR0C register

T E

S y s t e m C l o c k

T N 1
T N 0

T M R 0

T N 1
T N 0

T O N

P u l s e W

i d t h

M e a s u r e m e n t

M o d e C o n t r o l

T i m e r / E v e n t C o u n t e r 0

P r e l o a d R e g i s t e r

T i m e r / E v e n t

C c o u n t e r 0

D a t a B u s

R e l o a d

O v e r f l o w
t o I n t e r r u p t

R O M
C o d e

O p t i o n

M
U
X

T N 2

S y s t e m C l o c k / 4

T

Q

P F D 0

P A 3 D a t a C T R L

R T C O u t

f

I N T

Timer/Event Counter 0