Effect of crosstalk, Influence quantities – Rainbow Electronics AT73C502 User Manual

Page 25

Advertising
background image

AT73C500

25

The measurements are done according to IEC1036 specifi-
cation. The results are averaged over a period of 10s.
Before measurements, AT73C500 devices have been
operational for minimum 1h.

Effect of Crosstalk
The error caused by crosstalk from one current input to
other two current inputs when the meter is carrying a sin-
gle-phase load.

Influence Quantities
The additional error caused by different influence quanti-
ties.

Table 9. Measurement Bandwidth

Parameter

Min

Typ

Max

Units

General, 50 Hz line
frequency

- high limit (-3dB)

750

Hz

- low limit (-3dB)

30

Hz

Reactive Power and
Energy, Voltage and
Current Measurement

- high limit

360

Hz

- low limit

40

Hz

Line Frequency

- high limit

350

Hz

- low limit

20

Hz

Table 10. Maximum Error

Current

Voltage

Power
Factor

Min

Typ

Max

Units

0.05I

B

U

N

1.000

-0.4

+0.4

%

0.1I

B

...I

FS

U

N

1.000

-0.2

+0.2

%

0.1I

B

U

N

0.5

lagging

-0.4

+0.4

%

0.2I

B

...I

FS

U

N

0.5

lagging

-0.4

+0.4

%

0.1I

B

U

N

0.8

leading

-0.4

+0.4

%

0.2I

B

...I

FS

U

N

0.8

leading

-0.4

+0.4

%

0.2I

B

...I

FS

U

N

0.25

lagging

-1.0

+1.0

%

Table 11. Single-phase Load Error

Current

Voltage

Power

Factor

Min

Typ

Max

Units

0.1I

B

...I

FS

U

N

1.000

-0.5

+0.5

%

0.1I

B

...I

FS

U

N

0.5

lagging

-0.5

+0.5

%

Table 12. Voltage Variation Error

Current

Voltage

Power
Factor

Min

Typ

Max

Units

0.1I

B

0.9U

N

...

1.1U

N

1.000

-0.2

+0.2

%

0.1I

B

0.9U

N

...

1.1U

N

0.5

lagging

-0.2

+0.2

%

Advertising