Starting current, Temperature coefficient, Other parameters – Rainbow Electronics AT73C502 User Manual

Page 27

Advertising
background image

AT73C500

27

Starting Current
As default, the starting current is based on 5A basic current
and 80A full scale current range.

Temperature Coefficient
Measured with the internal reference voltage source of
AT73C501/AT73C502.

Other Parameters
The accuracy of the following parameters is measured in
the conditions below unless otherwise indicated in the
parameter field of the table. The measurement error has
been calculated based on values averaged over 1min
period.

The accuracy of Power Factor measurements was tested
with PF values 0.5, -0.5, -1 and 1.

Table 18. Starting Current

Voltage

Min

Typ

Max

Units

U

N

0.004

IB

Table 19. Mean Temperature Coefficient

Current

Voltage

Power
Factor

Min

Typ

Max

Units

0.1I

B

...I

FS

U

N

1.000

0.02

0.04

%/K

0.1I

B

...I

FS

U

N

0.5

lagging

0.02

0.04

%/K

Parameter

Nominal Value

Nominal voltage, U

N

230V,

±

1%

Full-scale voltage, U

FS

270V

Full-scale current, I

FS

80A

Base current, I

B

5A

Frequency, f

50.0 Hz,

±

0.3%

Power factor, PF

1

Harmonic contents of voltage

0%

Harmonic contents of current

0%

Temperature, T

23C,

±

2

°

C

AT73C500 master clock

3.2768 MHz

Table 20. Apparent Power and Energy Error

Current

Min

Typ

Max

Units

0.05I

FS

...I

FS

-0.5

+0.5

%

0.005I

FS

...0.05I

FS

-2.0

+2.0

%

0.001I

FS

...0.005I

FS

-5.0

+5.0

%

Table 21. Power Factor Error

Current

Min

Typ

Max

Units

0.05I

FS

...I

FS

-0.5

+0.5

%

0.005I

FS

...0.05I

FS

-2.5

+2.5

%

Table 22. Phase Voltage Error

Voltage

Min

Typ

Max

Units

0.2U

FS

...U

FS

-0.5

+0.5

%

Table 23. Phase Current Error

Current

Min

Typ

Max

Units

0.05I

FS

...I

FS

-0.5

+0.5

%

0.005I

FS

...0.05I

FS

-2.5

+2.5

%

Table 24. Frequency Error

Frequency

Min

Typ

Max

Units

40 Hz...100 Hz

-0.5

+0.5

%

Parameter

Nominal Value

Advertising