Prokit's Industries MT-1620 User Manual

Page 16

Advertising
background image

unsteady reading when test leads haven't reach
the circuit, it's normal because the meter is very
sensitivity. When test leads touch the circuit, you
can get the true reading.

3.2.3 DC Current

Range Resolution

Accuracy

40mA 10

A

 ((1.2% of rdg + 3 digits)

400mA 100

A

 ((1.2% of rdg + 3 digits)

10A 10mA

 ((2.0% of rdg + 10 digits)

- Overload Protection: mA ranges:

F 500mA/250V fuse (quick acting), 10A
range: unfused.

- Max. Input Current: mA Jack: 400mA, 10A Jack:

10A
-Voltage Drop : mA ranges: 5mV/1mA, 10A range:

10mV/1A

3.2.4 AC Current

Range Resolution

Accuracy

40mA 10

A

(1.5% of rdg + 5 digits)

400mA 100

A

(1.5% of rdg + 5 digits)

10A 10mA

(3.0% of rdg + 10 digits)

-Overload Protection: mA ranges:

- 15 -

Advertising