4.16 CONTINUITY TESTING

WARNING

When testing the circuit continuity, be sure

that the power of the circuit has been shut

down and all capacitors have been

discharged fully.

4.16.1 Connect the black test lead to the COM jack

and the red test lead to the

 jack.

4.16.2 Set the transform switch at the

range position.

4.16.3 put down the "FUNC." transformed at

continuity test.

4.16.4 Connect test leads across two points of the

circuit under testing.

4.16.5 If continuity exists

(i.e., resistance less than

about 40

), built-in buzzer will sound.

4.16.6 You can get reading from LCD.

NOTE:
 If the input open circuit (or the circuit resistance

measured is higher than 400

), then the figure

‘0L’ will be displayed.

4.17 FREQUENCY MEASURING

4.17.1 Connect the black test lead to the COM jack