4 slowdown speed, 5 speed2 and speed3 – R&M Materials Handling VARIABLE SPEED CONTROLS CMXC 022 Service Manual User Manual

Page 12

Advertising
background image

R&M Materials Handling, Inc.

4501 Gateway Boulevard

Springfield, Ohio 45502

P.: (937) 328-5100

FAX: (937) 325-5319

12/14

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

MS2

EP2

EP3

MS4

DI2

S2

S2

S2

S2

DI3

HSP

AP

HOLD

SP2

DI4

S12

S11

AP

SP3

DI5

S22

S21

S11/S21

HSP


Description of the control signals:

S1

Drive command forward

AP

Acceleration command

S11

Slowdown limit forward

S12

Stop-limit forward

SP2

Speed2

HSP

High speed

S2

Drive command reverse

HOLD

Hold speed command

S21

Slowdown limit reverse

S22

Stop-limit reverse

SP3

Speed3

3.4 Slowdown speed

S1

S21

S11

EP2

EP3

S2

Slowdown frequency is activated in EP2 and EP3 control modes when the slowdown limit circuit is opened. In EP2 there
are separate inputs for both limit switch, therefore it is possible to drive high speed in the slowdown area in the safe
direction. In EP3 there is only one input and therefore the speed is limited in both directions in the slowdown area. There
are two alternatives for the level of slowdown speed which are selected by switch S6-3 as follows:

S6-3 = 0

Slowdown speed is 20% of the maximum speed (set by switch S1)

S6-3 = 1

Slowdown speed is 35% of the maximum speed (set by switch S1)

3.5 Speed2 and Speed3

In MS4-control mode the lowest speed level is set by switch S2 and the highest level by switch S1. There are two
alternative settings for the speed2 and speed3, which are set as a percentage of the maximum speed by switch S6-3 as
follows:

S6-3 = 0

Speed2 is 20% of maximum speed and speed3 is 40% of maximum

S6-3 = 1

Speed2 is 30% of maximum speed and speed3 is 50% of maximum

Advertising