Standard duty resistor must be disconnected when heavy duty resistor DMHR01F90
is connected to terminals R+ and R

−−−−

.

1.2

Technical characteristics

Technical data

Power range

2.2 kW

Supply voltage

380 - 480 VAC +/-10%

Nominal supply frequency

48 – 62 Hz

Nominal current

5.1A

Digital control

S1, S2, DI3, DI4, DI5

Max output voltage

Equal to supply voltage

Control voltage range

48 VAC/115 +/- 10%. If control voltage is 230VAC, front
resistors (15k,2W) have to be connected to digital inputs

Output

Relay output for brake contactor

Ambient temperature

-10

o

C to 50

o

C

Humidity

95% N.C. (without dripping)

Degree of protection

Frequency converter + cover (IP20)

Dimensions (WxHxD)

134x195x123mm

Altitude

Output current must be reduced 1 % for every 100 m over
1000 m. For altitudes over 3000 m, manufacturer must be
consulted.

Pollution degree

Pollution degree 2 according to NEMA ICS-1, IEC664 and
UL840

Vibration

IEC68-2-6

Shock

IEC68-2-27

1.3

Normal operation

The inverter goes into the ready-to-run state within one second after the power supply is connected. During running
the inverter follows the operator’s speed reference according to the set acceleration/deceleration ramp. During
direction change the brake is kept open all the time. When drive command is switched off the inverter decelerates
to zero according to the set ramp and closes the mechanical brake.

1.4

Status indication leds (green and red)

The inverter indicates its operating state by two leds. Red led indicates “fault state” (driving is inhibited). Green led
indicates “ok-state”. Blinking of green led indicates that fault state has been active, but it has been recovered.
Normal driving is however possible also when green led is blinking (in other words, blinking of green led does not
indicate “warning-state”).

1.5

Programming switches

ON

DIP

1 2 3 4

ON

DIP

1 2 3 4

ON

DIP

1 2 3 4

ON

DIP

1 2 3 4

ON

DIP

1 2 3 4

ON

DIP

1 2 3 4

S1

S2

S3

S4

S5

S6

c

_

s

0

2

2

a

The programming of the inverter is performed by dip-switches. The state of each switch is either OFF (0) or ON (1).
It is possible to set he following parameters by the switches S1-S6.

S1 = Maximum speed
S2 = Minimimum speed
S3 = Acceleration / deceleration time