R&M Materials Handling VARIABLE SPEED CONTROLS CMXC 022 Service Manual User Manual

Page 7

Advertising
background image

R&M Materials Handling, Inc.

4501 Gateway Boulevard

Springfield, Ohio 45502

P.: (937) 328-5100

FAX: (937) 325-5319

7/14

R&M Materials Handling, Inc. reserves the right to alter or amend the above information without notice.

2 DESCRIPTION OF CONTROL MODES

2.1

MS2-control (S6-1=OFF & S6-2=OFF)

c_coms2a

A. Pushbutton position
B. Speed

S1 means “drive minimum speed forward”
S2 means “drive minimum speed reverse”
HSP means “maximum speed”
When S1 and S2 or are not active the inverter decelerates to zero

2.2

EP2-control (S6-1=ON & S6-2=OFF)

c_coep2a

0. Decelerate
1. Maintain speed
2. Accelerate
A. Pushbutton position
B. Speed

S1 means “drive forward”
S2 means “drive reverse”
AP means “accelerate”
When starting, S1 and S2 mean “accelerate to minimum speed”
When S1 and S2 are not active the inverter decelerates to zero
During running S1 and S2 mean “hold speed”
At maximum speed AP means “hold speed”