1 GENERAL

1.1 Technical

data

Power class

002F 003F 004F 005F 007F 011F 015F 018F 022F 030F 037F 045F 055F 075F 090F 110F

Power (kVA) at 400V

4.5 5.5 7 9 13 17 22 29 33 40 50 60 75 100

120

150

Output current In (A)

6.5 8 10 13 18 24 32 42 48 60 75 90 110

150

180

210

Max. current 1min (A)

10 12 15 20 27 36 48 63 72 90 113

135

165

225

270

315

Overloadability

1.5 x In , 1min/10min

Max. output voltage

Equal to supply voltage

Supply

Supply voltage

380-500VAC

Allowable voltage fluctuation

+/- 10%

Nominal supply frequency

50/60Hz +/- 5%

Signal input levels

Digital controls

S1, S2, DIA3, DIA4, DIA5, DID1, DID2, DID3, DID4, DID5: 42 … 240VAC; 15mA

Analog references

AIN1: -10 … +10V and AIN2: 0 … 10V; 200k

Ω; accuracy 0.5%

Encoder feedback

EA+/- and EB+/-; 0/24V; 3k

Ω; floating differential inputs

Control features

Control method

Open loop or closed loop vector control

Frequency control range

0 ... 250Hz

Frequency command

Potentiometer, motor potentiometer, 2-4-step controller or 0 ... 10V analog signal

Limit switch functions

Slowdown and stop limit inputs for both directions

Speed control range

Open loop vector control

s

N

... 100% (s

N

= motor nominal slip)

Closed loop vector control

0 ... 100%

Speed accuracy

Open loop vector control

1% of nominal speed at speed range 10 ... 100%

1/3 of motor nominal slip at speed below 10%

Closed loop vector control

0.01% of nominal speed

Extended speed range

100 ... 200%

Braking torque

150%

Protections

Stall prevention

During acceleration and constant speed

Motor overload protection

Thermistor based temperature measurement

Overload protection

Fault is detected if the current momentarily exceeds 280% of rated current

Undervoltage / blown fuse

Fault is detected if DC voltage drops below 333V

Overvoltage protection

Fault is detected if DC voltage exceeds 911V

Momentary power loss

Immediate fault stop

Inverter overtemperature

Temperature sensor on the heat sink

Mechanical brake

Circuit breaker

Braking transistor

Electronic supervision for the braking chopper and for the braking resistor

Ground fault

Provided by electronic circuitry

Overspeed / stall,

speed difference supervision

Independent measurement using pulse wheel or encoder

Ambient conditions

Ambient temperature

-10

°C ... +55°C (14°F ... 131°F) for ED≤60%

Storage temperature

-40

°C ... +60°C (-31°F ... 140°F) dry

Humidity <95%RH

(no

condensation)

Altitude

Maximum 1000m at In. Above 1000m: In reduces 1% per each 100m.

Above 3000m: consult factory.

Vibration

Operation: maximum displacement amplitude 3mm at 2-9Hz.

Maximum acceleration amplitude 0.5g (5m/s²) at 9-200Hz

Conforms to LV and EMC directives.