B.3.29. at+btlpm,n, B.3.30. at&v, B.3.31. atsnn – SENA Parani-ESD100-110-200-210 User Manual

Page 45: B.3.32. atsnn=mm

Advertising
background image

45

Description

Parani-ESD can have a user friendly name for easy identification. The name allows up to
30 alpha-numeric characters.

Reference

AT+BTINFO?, AT+BTINQ?

Example

AT+BTNAME=”My-Parani-ESD”

B.3.29. AT+BTLPM,n

Response

 OK

Purpose

Set low power mode

Parameters

n=0: Inactivate (Default)
n=1: Activate

Description

During no data transmission, Parani-ESD can be in low power mode to save the power. It
takes a few seconds to wake the Parani-ESD out of low power mode.

B.3.30. AT&V

Response

 S0:m0;S1:m1; …Sn:mn
 OK

Purpose

Display all the S-register

Description

All parameters are stored at S-register in flash memory. These values are sustained until
hardware reset.

Reference

ATS

B.3.31. ATSnn?

Response

 value
 OK

Purpose

Display a given S-register

Parameters

nn= Address of S-register

Description

A specific S-register will be displayed.

Reference

AT&V

B.3.32. ATSnn=mm

Response

 OK

Purpose

Change S-register value

Parameters

nn= Address of S-register
mm= New value of S-register

Description

Some S-registers are optimized for the overall performance and protected and cannot be
changed. When users try to change these S-registers, response is ‘ERROR’.
For details of S-register, refer Appendix. B.

Reference

AT&V

Example

ATS10=0