Figure 3-9 IP filtering Configuration for each service and serial port

Table 3-2 Input examples of Option and IP address/mask combination

Input format

Allowable Hosts

IP address/mask

Option

Any host

0.0.0.0/0.0.0.0

Normal

192.168.1.120

192.168.1.120/255.255.255.255

Normal

Any host except

192.168.1.120

192.168.1.120/255.255.255.255

Invert

192.168.1.1 ~

192.168.1.254

192.168.1.0/255.255.255.0

Normal

192.168.0.1 ~

192.168.255.254

192.168.0.0/255.255.0.0

Normal

192.168.1.1 ~

192.168.1.126

192.168.1.0/255.255.255.128

Normal

192.168.1.129 ~

192.168.1.254

192.168.1.128/255.255.255.128

Normal

None

0.0.0.0/0.0.0.0

Invert

3.6. SYSLOG Server Configuration

The Pro Series supports the use of a remote message logging service, SYSLOG service for the

system and port data logging. To use the remote SYSLOG service, the user must specify the

SYSLOG server’s IP address and the facility to be used. Figure 3-10 shows the SYSLOG server

configuration page which is located in the Web interface.