Figure 4-13 RC4 Cryptography configuration

4.2.6. Serial Port Parameters

To connect the serial device to the Pro Series serial port, the serial port parameters of the Pro Series

should match exactly to that of the serial device attached. The serial port parameters are required to

match this serial communication. The parameters required for the serial communication are: UART

type, baud rate, data bits, parity, stop bits, flow control and inter-character timeout.

UART type

First of all, the Pro Series and the serial device must agree on the serial communication type, which is

one of RS232 mode, RS422(RS485 full) mode or RS485 half mode. User can set the serial

communication type by using DIP switch near by serial port in case of PS110/410. To change the

serial communication type, change the position of each DIP switch as shown on Figure 4-14. For

PS810, user can change the serial communication type of each serial port using configuration menu

as shown on Figure 4-17.