ProBee-ZU10 User Guide Rev.1.5

ATZ<CR>

# Apply the change

OK

# Response

AT+NWKKEY=0<CR>

# set the 128-bit network key (random key)

OK

# Response

AT+UPDATEKEY<CR>

# update the changed network key

OK

# Response

6.4

UART Settings

AT+BAUDRATE=115200<CR>

# set baud rate (115,200bps)

OK

# Response

AT+DATABIT=8<CR>

# set data bit (8bit)

OK

# Response

AT+PARITY=0<CR>

# set parity (none)

OK

# Response

AT+STOPBIT=1<CR>

# set stop bit (1bit)

OK

# Response

AT+FLOWCTRL=2<CR>

# set flow control (hardware)

OK

# Response

ATZ<CR>

# Apply the change

OK

# Response

6.5

Firmware Upload

6.5.1

Local Node

# enter the bootloader menu for uploading firmware. Note that UART of local
node should be set to 115200-8-N-1-N.

AT+BOOTLOAD<CR>

Press Enter…

EM250 Bootloader v20 b09

1. upload ebl

2. run

3. ebl info

BL >

# press “1” and upload ebl file by X-modem

begin upload

CCCCCCCCCCCCC

Serial upload complete

# press “2” or reset after upload is done