Emc considerations, Lineage power 13 – GE Industrial Solutions EVW020A0S6R0 Series (Eighth-Brick) User Manual
Page 13
Data Sheet
March 3, 2011
EVW020A0S6R0 Series Eighth-Brick Power Modules
36–75Vdc Input; 6.0Vdc Output; 20A Output Current
LINEAGE
POWER
13
EMC Considerations
The circuit and plots in Figure 26 shows a suggested configuration to meet the conducted emission limits of EN55022
Class B.
Figure 26. EMC Considerations
For further information on designing for EMC compliance, please refer to the FLT007A0 data sheet (DS05-028).
-10
0
10
20
30
40
50
60
70
Level [dBµV]
150k
300k
500k
1M
2M
3M
5M
7M
10M
30M
Frequency [Hz]
x
xx
xxxx
x
x
x
x
MES CE1102091326_fin QP
MES CE1102091326_pre PK
LIM EN 55022B V QP Voltage QP Limit
-10
0
10
20
30
40
50
60
70
Level [dBµV]
150k
300k
500k
1M
2M
3M
5M
7M
10M
30M
Frequency [Hz]
+
++
++++
+
+ +
+
MES CE1102091326_fin AV
MES CE1102091326_pre AV
LIM EN 55022B V AV Voltage AV Limit