Feature specifications – GE Industrial Solutions EVW020A0S6R0 Series (Eighth-Brick) User Manual

Page 4

Advertising
background image

Data Sheet

March 3, 2011

EVW020A0S6R0 Series Eighth-Brick Power Modules

36–75Vdc Input; 6.0Vdc Output; 20A Output Current

LINEAGE

POWER

4

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions. See Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current

All

I

on/off

0.3 1.0 mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

1.0 V

dc

Logic High Voltage – (Typ = Open Collector)

All

V

on/off

2.0 5 V

dc

Logic High maximum allowable leakage current

All

I

on/off

10

μA

Turn-On Delay

1

and Rise Times

(I

O

=I

O, max ,

V

IN

=V

IN, nom,

T

A

= 25

o

C)

Case 1: Input power is applied for at least 1 second,
and then the On/Off input is set from OFF to ON (T

delay

from instant at which V

IN

=V

IN, min

until V

O

=10% of V

O, set

).

All T

delay

― 15 msec

Case 2: On/Off input is set to ON, and then input power

is applied (T

delay

from instant at which V

IN

= V

IN, min

until

V

o

=10% of V

O,set

)

All T

delay

― 150 msec

Output voltage Rise time (time for V

o

to rise from 10%

of V

o,set

to 90% of V

o, set

)

All T

rise

― 5 10 msec

Output voltage overshoot – Startup

All

― 3

%

V

O, set

I

O

= I

O, max

, V

IN

=V

IN, min

to V

IN, max

, T

A

= 25

o

C

Remote Sense Range

All

V

SENSE

10 %

V

O, set

Output Voltage Adjustment Range

2

All 5.0 7.0 V

dc

Output Overvoltage Protection

All V

O, limit

7.5

9.5 V

dc

Overtemperature Protection – Hiccup Auto Restart

All

T

ref

128

O

C

Input Undervoltage Lockout

All

V

UVLO

Turn-on Threshold

32 34 36 V

dc

Turn-off Threshold

30 32 34 V

dc

Hysteresis

1

2

V

dc

Notes:
1. The module has an adaptable extended Turn-On Delay interval, T

delay

, of 4 seconds. The extended T

delay

will occur when the module restarts

following either: 1) the rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout (which causes module shutdown), and
then back to normal; or 2) toggling the on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay
interval, T

delay

, will occur whenever a module restarts with input voltage removed from the module for the preceding 1 second.

2. Maximum trim up possible only for Vin>40V. Maximum rated power = V

O,set

x I

O,max

. See Feature Descriptions for more details.