Data sheet, Feature specifications – GE Industrial Solutions EVK011A0B Series (Eighth-Brick) User Manual

Page 4

Advertising
background image

GE

Data Sheet

EVK011A0B Series (Eighth-Brick) DC-DC Converter Power Modules

36–60Vdc Input; 12.0Vdc Output; 11A Output Current

May 15, 2013

©2012 General Electric Company. All rights reserved.

Page 4

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Remote On/Off Signal Interface

(V

IN

=V

IN, min

to V

IN, max

; open collector or equivalent,

Signal referenced to V

IN-

terminal)

Negative Logic: device code suffix “1”

Logic Low = module On, Logic High = module Off

Positive Logic: No device code suffix required

Logic Low = module Off, Logic High = module On

Logic Low - Remote On/Off Current

All

I

on/off

1.0 mA

Logic Low - On/Off Voltage

All

V

on/off

-0.7

1.0 V

dc

Logic High Voltage – (Typ = Open Collector)

All

V

on/off

2.0 5.0 V

dc

Logic High maximum allowable leakage current

All

I

on/off

10

μA

Turn-On Delay

1

and Rise Times

(I

O

=I

O, max ,

V

IN

=V

IN, nom,

T

A

= 25

o

C)

Case 1: On/Off input is set to Logic Low (Module
ON) and then input power is applied (T

delay

from

instant at which V

IN

= V

IN, min

until V

O

= 10% of V

O,set

)

All T

delay

— 25 30 msec

Case 2: Input power is applied for at least 1 second

and then the On/Off input is set from OFF to ON (T

delay

from

instant V

on/off

toggles until V

O

= 10% of V

O, set

).

All T

delay

— 12 20 msec

Output voltage Rise time (time for Vo to rise from 10%
of V

o,set

to 90% of V

o, set

)

All T

rise

— 10 15

msec

Output voltage overshoot – Startup

All

— 3

%

V

O, set

I

O

= I

O, max

; V

IN

=V

IN, min

to V

IN, max

, T

A

= 25

o

C

Remote Sense Range

All

V

SENSE

10

%

V

O, set

(Max voltage drop is 0.5V)

Output Voltage Adjustment Range

2

All 80 110

%

V

O, set

Output Overvoltage Protection

All V

O, limit

13.8

16.5 V

dc

Input Undervoltage Lockout

All

V

UVLO

Turn-on Threshold

30 34.5 36 V

dc

Turn-off Threshold

30 32.5

V

dc

Hysterisis

1.5

2.0

V

dc

Input Overvoltage Lockout

All

V

OVLO

Turn-off Threshold

64 66 V

dc

Turn-on Threshold

60 62

V

dc

Hysterisis

1

2

V

dc

Notes:
1. The module has an adaptable extended Turn-On Delay interval, T

delay

, of 4 seconds. The extended T

delay

will occur when the module restarts following either: 1) the

rapid cycling of Vin from normal levels to less than the Input Undervoltage Lockout (which causes module shutdown), and then back to normal; or 2) toggling the
on/off signal from on to off and back to on without removing the input voltage. The normal Turn-On Delay interval, T

delay

, will occur whenever a module restarts with

input voltage removed from the module for the preceding 1 second.

2. Maximum trim up possible only for Vin>40V.

Advertising