Data sheet, Thermal considerations, Through-hole soldering information – GE Industrial Solutions EVK011A0B Series (Eighth-Brick) User Manual

Page 9

Advertising
background image

GE

Data Sheet

EVK011A0B Series (Eighth-Brick) DC-DC Converter Power Modules

36–60Vdc Input; 12.0Vdc Output; 11A Output Current

May 15, 2013

©2012 General Electric Company. All rights reserved.

Page 9

Thermal Considerations

(continued)

Heat-dissipating components are mounted on the top side

The thermal reference points, T

ref1

and T

ref2

used in the

specifications for open frame modules is shown in Figure 13.
For reliable operation T

ref1

should not exceed 128

o

C, and T

ref2

should not exceed 123

o

C .

Figure 13. T

ref

Temperature Measurement Location for open

Frame Module.

Heat Transfer via Convection

Increased airflow over the module enhances the heat
transfer via convection. Derating curves showing the
maximum output current that can be delivered by the open

frame module versus local ambient temperature (T

A

) for natural

convection and up to 1.5m/s (300 ft./min) forced airflow are

shown in Figure 14.

OUTPUT C

U

RR

EN

T,

I

O

(A

)

AMBIENT TEMEPERATURE, T

A

(

o

C

)

Figure 14. Output Current Derating for the Open Frame
Module; Airflow in the Transverse Direction from Vout(+) to
Vout(-); Vin =48V.
Please refer to the Application Note “Thermal Characterization

Process For Open-Frame Board-Mounted Power Modules” for a
detailed discussion of thermal aspects including maximum
device temperatures.

Through-Hole Soldering Information

The RoHS-compliant (Z codes) through-hole products use the
SAC (Sn/Ag/Cu) Pb-free solder and RoHS-compliant components.
The RoHS-compliant with lead solder exemption (non-Z codes)
through-hole products use Sn/Pb solder and RoHS-compliant
components. Both non-Z and Z codes are designed to be
processed through single or dual wave soldering machines. The

pins have an RoHS-compliant finish that is compatible with both

Pb and Pb-free wave soldering processes. A maximum
preheat rate of 3C/s is suggested. The wave preheat
process should be such that the temperature of the
power module board is kept below 210C. For Pb solder,
the recommended pot temperature is 260C, while the
Pb-free solder pot is 270C max. Not all RoHS-
compliant through-hole products can be processed with
paste-through-hole Pb or Pb-free reflow process. If
additional information is needed, please consult with

your GE representative for more details.

Post Solder Cleaning and Drying Considerations

Post solder cleaning is usually the final circuit-board
assembly process prior to electrical board testing. The
result of inadequate cleaning and drying can affect both
the reliability of a power module and the testability of
the finished circuit-board assembly. For guidance on
appropriate soldering, cleaning and drying procedures,
refer to GE Board Mounted Power Modules: Soldering
and Cleaning
Application Note (AN04-001).

Advertising