Car0812fp series rectifier, Data sheet, Input: 85v – GE Industrial Solutions CAR0812FP series User Manual

Page 3: Output: 12v, Or 5 v, General specifications, Feature specifications

Advertising
background image

GE

Data Sheet

CAR0812FP series rectifier

Input: 85V

AC

to 264V

AC

; Output: 12V

DC

@ 850W; 3.3V

DC

or 5 V

DC

@ 1A

May 2, 2013

©2013 General Electric Company. All rights reserved.

Page 3

12V

dc

MAIN OUTPUT (continued)

Parameter

Symbol

Min

Typ

Max

Unit

Turn-ON delay

T

2

sec

Remote ON/OFF delay time

40

ms

Turn-ON rise time (10 – 90% of V

OUT

)

50

ms

Transient response 50% step [10%-60%, 50% - 100%]

(di/dt – 1A/µs, recovery 500µs)

V

OUT

-5 +5

%V

OUT

Programmable range (hardware & software)

10.8

13.2

V

DC

Overvoltage protection, latched
(recovery by cycling OFF/ON via hardware or software)

13.5 14.5 15.5

V

DC

Output current

I

OUT

0 71

A

DC

Current limit, Hiccup (level programmable)

106

125

% of FL

Active current share – greater than 20% load

-5

+5

% of FL

STANDBY OUTPUT

Parameter

Symbol

Min

Typ

Max

Unit

Set point

V

OUT

3.3 / 5.0

V

DC

Overall regulation (load, temperature, aging)

V

OUT

-5

+5 %

Ripple and noise

50

mVp-p

Output current

I

OUT

0 1

A

DC

Isolation Output/Frame

100

V

DC

General Specifications

Parameter

Min

Typ

Max

Units

Notes

Reliability

300,000
100,000

hrs

Full load, 25C per Bellcore RPP
Full load, 50C per Bellcore RPP

Service Life

10

Yrs

Full load, excluding fans

Weight

1.09

(2.4)

Kgs

(Lbs)

Feature Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See Feature

Descriptions for additional information.

Parameter

Symbol

Min

Typ

Max

Unit

Remote ON/OFF (Needs to be pulled HI via an external resistor)

Logic High (Module ON)

I

IH

20 µA

V

IH

0.7V

DD

12 V

DC

Logic Low (Module OFF)

I

IL

1 mA

V

IL

0

0.8 V

DC


Advertising