Car0812fp series rectifier, Data sheet, Input: 85v – GE Industrial Solutions CAR0812FP series User Manual

Page 5: Output: 12v, Or 5 v, Feature specifications (continued), Digital interface specifications

Advertising
background image

GE

Data Sheet

CAR0812FP series rectifier

Input: 85V

AC

to 264V

AC

; Output: 12V

DC

@ 850W; 3.3V

DC

or 5 V

DC

@ 1A

May 2, 2013

©2013 General Electric Company. All rights reserved.

Page 5

Feature Specifications (continued)

Parameter

Symbol

Min

Typ

Max

Unit

SMBAlert# (Interrupt) (Needs to be pulled HI via an external resistor)

Logic High (No Alert - normal)

I

OH

20 µA

V

OH

0.7V

DD

12 V

DC

Logic Low (Alert is set)

I

OL

4 mA

V

OL

0

0.4 V

DC

Output current monitor (Imon)

Resolution

40 mV/A

Accuracy, load greater than 25%

-10

10

%

Measurement range

I

o

0 80 A

DC

Analog output range

V

mon

0 3 V

DC

Sourced output current

I

o

5 mA

DC

Digital Interface Specifications

Parameter

Conditions

Symbol

Min

Typ

Max

Unit

PMBus Signal Interface Characteristics
Input Logic High Voltage (CLK, DATA)

V

IH

2.1 3.6 V

DC

Input Logic Low Voltage (CLK, DATA)

V

IL

0 0.8 V

DC

Input high sourced current (CLK, DATA)

I

IH

0 10 μA

Output Low sink Voltage (CLK, DATA, SMBALERT#)

I

OUT

=3.5mA V

OL

0.4 V

DC

Output Low sink current (CLK, DATA, SMBALERT#)

I

OL

3.5

mA

Output High open drain leakage current (CLK,DATA,
SMBALERT#)

V

OUT

=3.6V I

OH

0 10 μA

PMBus Operating frequency range

Slave Mode

F

PMB

10 400 kHz

Measurement System Characteristics (all measurement tolerances are typical estimations under normal operating conditions)

Clock stretching

t

STRETCH

25

ms

I

OUT

measurement range

Linear

I

RNG

0 80 A

DC

I

OUT

measurement accuracy 25°C

I

ACC

-5 +5 %

V

OUT

measurement range

Linear

V

OUT(rng)

0

14

V

DC

V

OUT

measurement accuracy

V

OUT(acc)

-5 +5 %

Temp measurement range

Linear

Temp

(rng)

0

120

C

Temp measurement accuracy

5

Temp

(acc)

-5 +5 %

I

IN

measurement range

Linear

I

IN(rng)

0 15 A

AC

I

IN

measurement accuracy

I

IN(acc)

-5 +5 %

V

IN

measurement range

Linear

V

IN(rng)

0 300 V

AC

V

IN

measurement accuracy

V

IN(acc)

-5 +5 %

P

IN

measurement range

Linear

P

N(rng)

0 1000 W

P

IN

measurement accuracy

P

IN(acc)

-5 +5 %

Fan Speed measurement range

Linear

0 30k RPM

Fan Speed measurement accuracy

-10 10 %

Fan speed control range

Linear

0 100 %

5

Temperature accuracy reduces non-linearly with decreasing temperature

Advertising