15

output capacitance will be required. Table 3 lists
recommended values of R

TUNE

and C

TUNE

in order

to meet 2% output voltage deviation limits for some
common output voltages in the presence of a 15A
to 30A step change (50% of full load), with an input
voltage of 12V.

Please contact your Lineage Power technical
representative to obtain more details of this feature
as well as for guidelines on how to select the right
value of external R-C to tune the module for best
transient performance and stable operation for other
output capacitance values or input voltages other
than 12V.

Table 2. General recommended values of of
R

TUNE

and C

TUNE

for Vin=12V and various

external ceramic capacitor combinations.


Table 3. Recommended values of R

TUNE

and

C

TUNE

to obtain transient deviation of

2% of

Vout for a 15A step load with Vin=12V.

Vo

3.3V

2.5V

1.8V

1.2V

0.8V

Co

2x47

μF

+

3x330

μ

F

Polyme

r

3x47

μF +

3x330

μF

Polymer

3x47

μF

+

4x330

μF

Polymer

7x330

μF

Polymer

2x47

μF+

10

x330

μF

Polymer

R

TUNE

390 390 330 220 150

C

TUNE

2200pF 3900pF 6800pF 10nF

56nF

ΔV

66mV 50mV 36mV 24mV 16mV































Co

1x47

μF 2x47μF 4x47μF 10x47μF 20x47μF

R

TUNE

560 390 390 220 220

C

TUNE

270pF 470pF 820pF 2200pF 4700pF