Absolute maximum ratings, Electrical specifications – GE Industrial Solutions 12V Mega TLynx User Manual

Page 2

Advertising
background image

Data Sheet
May 4, 2012

12V Mega TLynx

TM

: Non-Isolated DC-DC Power Modules:

6.0 – 14Vdc Input; 0.8Vdc to 3.63Vdc Output; 30A output

current

LINEAGE

POWER

2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are
absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in
excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for
extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

Continuous All

V

IN

-0.3 15 Vdc

Sequencing pin voltage

All

Vs

EQ

-0.3 15

Vdc

Operating Ambient Temperature

All

T

A

-40 85

°C

(see

Thermal

Considerations

section)

Storage Temperature

All

T

stg

-55 125

°C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

6.0

12

14

Vdc

Maximum Input Current

All

I

IN,max

19 Adc

(V

IN

= V

IN,min

, V

O

= V

O,set,

I

O

=I

O, max

)

Inrush Transient

All

I

2

t

1 A

2

s

Input No Load Current

V

O,set

= 0.8 Vdc

I

IN,No load

91

mA

(V

IN

= 12.0Vdc, I

O

= 0, module enabled)

V

O,set

= 3.3Vdc

I

IN,No load

265

mA

Input Stand-by Current

All

I

IN,stand-by

20

mA

(V

IN

= 12.0Vdc, module disabled)

Input Reflected Ripple Current, peak-to-
peak
(5Hz to 20MHz, 1μH source impedance;
V

IN

=6.0V to 14.0V, I

O

= I

Omax

; See Figure 1)

All

100

mAp-p

Input Ripple Rejection (120Hz)

All

50

dB