G output strip, G input strip, Ge others – GE Industrial Solutions ZBTE Series User Manual

Page 6: Ge zenith, Controls, Others, Ge zenith controls, Non-bypass ats bypass ats

Advertising
background image

91

R

-1000

Page 4

Zenith ZTE/ZBTE Series Operation & Maintenance Manual

Figure 3
Representative Schematic of Terminal Board, Output Strip and Input Strip

Refer to Electrical Schematic Drawing for additional details

CUSTOMER USE

A1

OUT5

11

MX350 C

ONTR

OLLER

TO

L-CARD SL

O

T “G” ON

G OUTPUT STRIP

OUTPUT-5

12

A2

14

5-3

5-2

L5
L6

L4

L3

L2

L1

G2

G6

G4

G5

G3

J8

G1

800

802

J7

2

1

-

+

OUTPUT-4

FACTORY USED (FOR ALARM)

FOR CUSTOMER USE

STATUS OUTPUT CONTACT

SHUNT TRIP EMERG. BKR.

LOAD SHED
STATUS OUTPUT CONTACT
FOR CUSTOMER USE

GE ZENITH

12

12

OUT4

A1

A2

OUT3

A1

A2

14

11

11

14

CONTROLS

12

12

A1

OUT1

OUT2

A2

A1

A2

11

14

11

14

802

4-2

4-3

5-1

4-1

3-3

3-2

2-3

3-1

1-3

2-2

1-2

2-1

1-1

(-)

OUTPUT
CONTACTS FOR

CONFIGURABLE

OTHERS

G INPUT STRIP

L9

MX350 C

O

NTR

OLLER

TO

L-CARD SL

O

T “G” ON

L13
L14

L12

L11

L10

G9

G13
G14

G12

G10
G11

L7
L8

802

800

J6

G8

G7

1

2

J5

-

+

(SUPPLIED BY OTHERS)

(SUPPLIED BY OTHERS)

(SEE NOTE 3)

(SEE NOTE 4)

(SEE NOTE 8)

C

C

NO

12

12

12

IN7

A2

A1

IN5

IN6

A2

A1

A2

A1

14

11

14

11

14

11

COM

13

12

25ZA

NO

NO

C

C

C

C

IN1

11

A1

12

12

12

12

IN3

A1

IN4

A1

A2

A2

IN2

A1

A2

A2

11

11

14

14

11

14

14

GE ZENITH

CONTROLS

11

10

9

7

8

R15

NO

NO

C

C

C

C

Q2

DS

NO

C

FOR CUST

OMER USE

C

O

NFIGURABLE INPUTS OPTION P

A

CKA

GE

OTHERS

COM

COM

CONNECTIONS OF THE TRANSFER SWITCH.

COMPONENTS DRAWN IN DASHED LINES ARE OPTION PACKAGE AND CUSTOMER

Q2 (TEST WITH LOAD) IS PROVIDED AS STANDARD (PRE-CONFIGURED) FEATURE.
R15 (LOAD SHED) IS PROVIDED AS AN OPTION (PRE-CONFIGURED) FEATURE.

ATS SHOWN IN SOURCE-1 POSITION WITH NO POWER AVAILABLE.

UNLESS OTHERWISE SPECIFIED ALL CUSTOMER CONNECTION WIRES TO BE #14 AWG.,

OUTPUT STRIP CONTACTS ARE RATED 10 AMPS AT 30VDC/250VAC.

ENGINE START CONTACT IS RATED 10 AMPS AT 28VDC/120VAC.

600V.

6.
7.

5.

4.

3.

2.

1.

NOTES

8. ENGINE START CONTACT MAY BE ON SEPARATE TERMINAL BLOCK FOR BYPASS
SWITCHES. REFER TO ELECTRICAL SCHEMATIC FOR TERMINAL LOCATION.

GE

OTHERS

A4-1

A3-1

A3-2

CARD

8

K

8

C

C

C

7

9

E12

E11

E13

NO

NO

NO

A3-2

CA3-1

A3-1

CA4-1

A4-1

CA3-2

A4-2

C

AUX

NO

CA4-2

A4-2

CLOSED IN SOURCE 2 POSITION.

(2) NORMALLY OPEN CONTACTS.

FOR CUSTOMER USE.

FOR CUSTOMER USE

CONTACT

E

ENGINE START CONTACT

(2) NORMALLY OPEN CONTACTS

TB

FOR CUSTOMER USE.

HELD CLOSED IN SOURCE 1 POSITION

CARD

K

TB

ENG. START

98

8

7

8

9

PA3

TP1

E11

E13

E12

NO

NO

NO

NO

NO

NO

C

AB4-5

AB3-6

C

C

A3-1

C

A4-1

A3-2

C

A4-2

C

CA3-1

101

100

A3-1

CA3-2

99

CA4-1

CA4-2

A3-2

A4-1

A4-2

AUX

GE

OTHERS

(2) NORMALLY OPEN
CONTACTS, HELD CLOSED IN
SOURCE 1 POSITION FOR
CUSTOMER USE. SEE NOTE 1

(2) NORMALLY OPEN
CONTACTS, CLOSED IN
SOURCE 2 POSITION
FOR CUSTOMER USE.

IS IN SOURCE 1 POSITION.

CONTACT CLOSED WHEN BYPASS

FOR CUSTOMER USE.
CONTACT CLOSED WHEN BYPASS
IS IN SOURCE 2 POSITION.
FOR CUSTOMER USE.

CONTACT

E

FOR CUSTOMER USE

ENGINE START CONTACT

Non-Bypass ATS

Bypass ATS