STATUS_WORD [0x79]

Command support: full implementation for supported functions (note: Fans, MFR_SPECIFIC, Unknown not supported)

Format

8 bit unsigned (bit field)

Bit

Position 15 14 13

12

11 10 9 8

Access

r r r

r

r r r r

Function VOUT

I/POUT

INPUT

MFR_SPEC

1

#PWR_

GOOD

FANS

1

OTHER

1

UN

KNOWN

1

Format

8 bit unsigned (bit field)

Bit Position

7

6

5

4

3

2

1

0

Access r

r

r r r

r

r

r

Function

BUSY

1

OUTPUT

_OFF

VOUT_OV

_FAULT

IOUT_OC _FAULT

VIN_UV
_FAULT

TEMP CML NONE OF

ABOVE

1

(1) Not supported

STATUS_VOUT [0x7A]

Command support: VOUT_OV_FAULT support, all bit reset supported

Format

8 bit unsigned (bit field)

Bit

Position

7 6 5 4 3 2 1 0

Access

r/reset(1)

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset r/

reset r/

reset

Function

VOUT_OV

_FAULT

VOUT_OV

_WARN

1

VOUT_UV

_WARN

1

VOUT_UV

_FAULT

1

VOUT_

MAX

_WARN

1

TON_

MAX_

FAULT

1

TOFF_

MAX_

WARN

1

VOUT

TRACKING

ERROR

1

(1) Not supported

STATUS_IOUT [0x7B]

Command support: IOUT_OC_FAULT support, all bit reset supported

Format

8 bit unsigned (bit field)

Bit

Position

7 6 5 4 3 2 1 0

Access

r/ reset(1)

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset

Function

IOUT_OC

_FAULT

IOUT_OC _LV

_FAULT

1

IOUT_OC

_WARN

IOUT_UC

_FAULT

1

Current Share

Fault

1

In Power

Limiting

Mode

1

POUT_OP

_FAULT

1

POUT_OP

_WARN

1

(1) Not supported

STATUS_INPUT [0x7C]

Command support: VIN_OV_FAULT support, all bit reset supported

Format

8 bit unsigned (bit field)

Bit

Position

7 6 5 4 3 2 1 0

Access

r/ reset(1)

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset

Function

VIN_OV
_FAULT

VIN_OV

_WARN

1

VIN_UV

_WARN

1

VIN_UV
_FAULT

Unit Off

(low input

voltage)

IIN_OC

_FAULT

1

IIN_OC

_WARN

1

PIN_OP

_WARN

1

(1) Not supported

STATUS_TEMPERATURE [0x7D]

Command support: OT_WARN, OT_FAULT supported, all bit reset supported

Format

8 bit unsigned (bit field)

Bit

Position

7 6 5 4 3 2 1 0

Access

r/ reset(1)

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset

r/ reset

Function

OT_ FAULT

OT_ WARN

UT_ WARN

1

UT_

FAULT

1

reserved reserved reserved reserved

(1) Not supported