Data Sheet

November 29, 2010

PIM300X Series; ATCA Board Power Input Modules

-38 to -75Vdc; 300W Input

LINEAGE

POWER

7

Characteristic Curves

The following figures provide typical characteristics for the PIM300X modules at 25ºC.

Figure 1. Inrush Current

CH1: -48_AF, CH2: -48V_OUT,

CH4: Iin(-48_AF)

Test Conditions:

-48_AF=-48Vdc, -48V_BF=0Vdc

PIM300F @ Max Load (Pin=300W)

C_FLTR=200

μF, C_HLDP=4X470μF

Figure 2. Inrush Current

(Expanded view of the first surge current)

CH1: -48_AF, CH2: -48V_OUT,

CH4: Iin(-48_AF)

Test Conditions:

-48_AF=-48Vdc, -48V_BF=0Vdc

PIM300F @ Max Load (Pin=300W)

C_FLTR=200

μF, C_HLDP=4X470μF

Figure 3. Power Up into Shorted Output

CH1: -48_AF, CH3: -48V_OUT,

CH2: Iin(-48_AF)

Test Conditions:

-48_AF=-48Vdc, -48V_BF=0Vdc

PIM300F @ No Load

C_FLTR=200

μF, C_HLDP=4X470μF

Figure 4. OR’ing Functionality when Feed B is
shorted

CH1: -48V_OUT(AC), CH2: Iin(-48_AF)

CH3: Iin(-48_BF), CH4: 3.3V Output

Test Conditions:

-48_AF=-48Vdc, -48V_BF=-50Vdc

I(-48V_OUT) = 1A

C_FLTR=200

μF, C_HLDP=4X470μF