November 29, 2010

PIM300X Series; ATCA Board Power Input Modules

-38 to -75Vdc; 300W Input

LINEAGE

POWER

9

Characteristic Curves

(continued)

The following figures provide typical characteristics for the PIM300X modules at 25ºC (unless specified otherwise).

Figure 9. Typical Start-Up of
MGMT_PWR(3.3Vdc) with application of

–48Vin.

CH1: -48_AF

CH2: MGMT_PWR (3.3Vdc) Output

Test Conditions:

1.

–48_AF=-48Vdc;

2. PIM300F @ Max Load (Pin=300W)

3. C_FLTR=200

μF, C_HLDP=4X470μF

Figure 10.

–48V_ALARM with Loss of Feed

CH1: -48V_AF

CH2: -48_ALARM

Test Conditions:

1.

–48_AF=-48_BF= -48Vdc ;

2. PIM300F @ Max Load (Pin=300W)

3. C_FLTR=200

μF, C_HLDP=4X470μF

Figure 11. Input Transient Over voltage
Protection for 100V/1ms transient

CH1: -48_AF, CH3: -48V_OUT, CH4: +12V Out

CH2: MGMT_PWR (3.3Vdc) Output

Test Conditions:

1.

–48_AF=-48Vdc to -100V for 1msec

2. -48V_OUT Load: QBW025A0B1 Bus Converter

3. MGMT_PWR Load = 3.3V @ 2.5 Ohms

Figure 12. Feeds Switchover Test from -48V_Feed A
to -75V_Feed B via Knife Switch

CH1: -48_BF, CH2: -48V_OUT, CH3: +12V Out

CH4: MGMT_PWR (3.3Vdc) Output

Test Conditions:

1.

–48_AF=-48Vdc

2. -48_BF= 0 to -75Vdc via Knife Switch

3. -48V_OUT Load: QBW025A0B1 Bus Converter