12a digital picodlynx, Non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12A Digital PicoDLynx User Manual

Page 2: Absolute maximum ratings, Electrical specifications

Advertising
background image

GE

Data Sheet

12A Digital PicoDLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 12A Output Current

November 19, 2013

©2013 General Electric Corporation.

All rights reserved.

Page 2

Absolute Maximum Ratings

Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.

Parameter

Device

Symbol

Min

Max

Unit

Input Voltage

All

V

IN

-0.3 15

V

Continuous

SEQ, SYNC, VS+

All

7

V

CLK, DATA, SMBALERT#

All

3.6

V

Operating Ambient Temperature

All

T

A

-40 85

°C

(see Thermal Considerations section)

Storage Temperature

All

T

stg

-55 125

°C

Electrical Specifications

Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.

Parameter

Device

Symbol

Min

Typ

Max

Unit

Operating Input Voltage

All

V

IN

3 ⎯

14.4 Vdc

Maximum Input Current

All

I

IN,max

9

Adc

(V

IN

=3V to 14V, I

O

=I

O, max

)

Input No Load Current
(V

IN

= 12Vdc, I

O

= 0, module enabled)

V

O,set

= 0.6 Vdc

I

IN,No load

52

mA

V

O,set

= 5Vdc

I

IN,No load

85

mA

Input Stand-by Current
(V

IN

= 12Vdc, module disabled)

All I

IN,stand-by

6.5

mA

Inrush Transient

All

I

2

t

1

A

2

s

Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 1μH source impedance; V

IN

=0 to

14V

,

I

O

= I

Omax

; See Test Configurations)

All

400

mAp-p

Input Ripple Rejection (120Hz)

All

-55

dB

Advertising