“Linear” mode with the exponent fixed at –10 (decimal). The
value of the offset voltage is given by

10

)

(

2

_

×

=

TRIM

VOUT

V

offset

OUT

This offset voltage is added to the voltage set through the
divider ratio and nominal V

REF

to produce the trimmed output

voltage. The valid range in two’s complement for this
command is –4000h to 3999h. The high order two bits of
the high byte must both be either 0 or 1. If a value outside of

the +/-25% adjustment range is given with this command,
the module will set it’s output voltage to the nominal value
(as if VOUT_TRIM had been set to 0), assert SMBALRT#, set

the CML bit in STATUS_BYTE and the invalid data bit in
STATUS_CML.

Output Voltage Margining Using the PMBus

The module can also have its output voltage margined via
PMBus commands. The command VOUT_MARGIN_HIGH sets
the margin high voltage, while the command
VOUT_MARGIN_LOW sets the margin low voltage. Both the
VOUT_MARGIN_HIGH and VOUT_MARGIN_LOW commands
use the “Linear” mode with the exponent fixed at –10
(decimal). Two bytes are used for the mantissa with the upper
bit [7] of the high byte fixed at 0. The actual margined output
voltage is a combination of the VOUT_MARGIN_HIGH or
VOUT_MARGIN_LOW and the VOUT_TRIM values as shown
below.

10

)

(

2

)

_

_

_

(

×

+

=

TRIM

VOUT

HIGH

MARGIN

VOUT

V

MH

OUT

10

)

(

2

)

_

_

_

(

×

+

=

TRIM

VOUT

LOW

MARGIN

VOUT

V

ML

OUT

Note that the sum of the margin and trim voltages cannot be

outside the ±25% window around the nominal output
voltage. The data associated with VOUT_MARGIN_HIGH and

VOUT_MARGIN_LOW can be stored to non-volatile memory
using the STORE_DEFAULT_ALL command.

The module is commanded to go to the margined high or low

voltages using the OPERATION command. Bits [5:2] are used
to enable margining as follows:

00XX

: Margin

Off

0101 : Margin Low (Ignore Fault)

0110 : Margin Low (Act on Fault)

1001 : Margin High (Ignore Fault)

1010 : Margin High (Act on Fault)

PMBus Adjustable Overcurrent Warning

The module can provide an overcurrent warning via the
PMBus. The threshold for the overcurrent warning can be set
using the parameter IOUT_OC_WARN_LIMIT. This command

uses the “Linear” data format with a two byte data word
where the upper five bits [7:3] of the high byte represent the
exponent and the remaining three bits of the high byte [2:0]

and the eight bits in the low byte represent the mantissa.
The exponent is fixed at –1 (decimal). The upper five bits of

the mantissa are fixed at 0 while the lower six bits are
programmable. . For production codes after April 2013, the
value for IOUT_OC_WARN_LIMIT will be fixed at 14.5A. For

earlier production codes the actual value for
IOUT_OC_WARN_LIMIT will vary from module to module due

to calibration during production testing. The resolution of this
warning limit is 500mA. The value of the
IOUT_OC_WARN_LIMIT can be stored to non-volatile memory
using the STORE_DEFAULT_ALL command.

Temperature Status via PMBus

The module can provide information related to temperature
of the module through the STATUS_TEMPERATURE
command. The command returns information about

whether the pre-set over temperature fault threshold and/or
the warning threshold have been exceeded.

PMBus Adjustable Output Over and Under Voltage

Protection

The module has output over and under voltage protection
capability. The PMBus command VOUT_OV_FAULT_LIMIT is
used to set the output over voltage threshold from four
possible values: 108%, 110%, 112% or 115% of the
commanded output voltage. The command
VOUT_UV_FAULT_LIMIT sets the threshold that

causes an

output under voltage fault and can also be selected from
four possible values: 92%, 90%, 88% or 85%. The default
values are 112% and 88% of commanded output voltage.
Both commands use two data bytes formatted as two’s
complement binary integers. The “Linear” mode is used with

the exponent fixed to –10 (decimal) and the effective over or
under voltage trip points given by:

10

)

_

(

10

)

_

(

2

)

_

_

_

(

2

)

_

_

_

(

Ч

=

Ч

=

LIMIT

FAULT

UV

VOUT

V

LIMIT

FAULT

OV

VOUT

V

REQ

UV

OUT

REQ

OV

OUT


Values within the supported range for over and
undervoltage detection thresholds will be set to the nearest
fixed percentage. Note that the correct value for

VOUT_SCALE_LOOP must be set in the module for the
correct over or under voltage trip points to be calculated.
In addition to adjustable output voltage protection, the 12A

Digital PicoDLynx

TM

module can also be programmed for the

response to the fault. The VOUT_OV_FAULT RESPONSE and

VOUT_UV_FAULT_RESPONSE commands specify the
response to the fault. Both these commands use a single
data byte with the possible options as shown below.

1. Continue operation without interruption (Bits [7:6]

= 00, Bits [5:3] = xxx)

2. Continue for four switching cycles and then shut

down if the fault is still present, followed by no
restart or continuous restart (Bits [7:6] = 01, Bits

[5:3] = 000 means no restart, Bits [5:3] = 111
means continuous restart)

3. Immediate shut down followed by no restart or

continuous restart (Bits [7:6] = 10, Bits [5:3] = 000
means no restart, Bits [5:3] = 111 means
continuous restart).

4. Module output is disabled when the fault is present

and the output is enabled when the fault no longer
exists (Bits [7:6] = 11, Bits [5:3] = xxx).

Note that separate response choices are possible for output
over voltage or under voltage faults.