Data Sheet

12A Digital PicoDLynx

TM

: Non-Isolated DC-DC Power Modules

3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 12A Output Current

November 19, 2013

©2013 General Electric Corporation.

All rights reserved.

Page 27


Table 6 (continued)

Hex

Code

Command

Brief Description

Non-Volatile

Memory Storage

36 VIN_OFF

Sets the value of input voltage at which the module turns off

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r

Function

Exponent Mantissa

Default Value

1 1 1 1 0 0 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

0 0 0 0 1 0 1 0

YES

38 IOUT_CAL_GAIN

Returns the value of the gain correction term used to correct the measured
output current

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r

r r/w

Function

Exponent Mantissa

Default Value

1 0 0 0 1 0 0 V

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

V: Variable based on factory calibration

YES

39 IOUT_CAL_OFFSET

Returns the value of the offset correction term used to correct the measured
output current

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r r

r

r

r/w

r r

Function

Exponent Mantissa

Default Value

1 1 1 0 0 V 0 0

Bit Position

7 6 5 4 3 2 1 0

Access

r r r/w

r/w

r/w

r/w

r/w r/w

Function

Mantissa

Default Value

0

0

V: Variable based on factory calibration

YES

40 VOUT_OV_FAULT_LIMIT

Sets the voltage level for an output overvoltage fault. Exponent is fixed at -10.

Format

Linear, two’s complement binary

Bit Position

7 6 5 4 3 2 1 0

Access

r r/w r/w

r/w

r/w

r/w

r/w r/w

Function

High Byte

Default Value

0 0 0 0 0 1 0 1

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r/w

r/w r/w

Function

Low Byte

Default Value

0 0 0 0 1 0 1 0

YES

41 VOUT_OV_FAULT_RESPONSE

Instructs the module on what action to take in response to a output overvoltage
fault

Format

Unsigned Binary

Bit Position

7 6 5 4 3 2 1 0

Access

r/w r/w r/w

r/w

r/w

r

r r

Function

RSP

[1]

RSP

[0]

RS[2] RS[1] RS[0]

X X X

Default Value

1 1 1 1 1 1 0 0

YES