GE Industrial Solutions Zephyr Non-Isolated SMT User Manual

Page 21

Advertising
background image

Zephyr Non-Isolated SMT DC-DC Power Module:

0.8V to 3.5V @ 20A Output, 5V to 12V Input

LINEAGE

POWER

21

Data Sheet
March 31, 2010

Environmental

Design including materials is consistent with environmental standards in Table 7.

Table 7. Environmental and Reliability Specifications

Operating Nonoperating

Temperature

Ambient 0

°C to 70 °C at zero to

400 LFM, full load (see Thermal Ratings)
with a maximum rate of change of
5

°C/10 minutes minimum but no more

than 10

°C/hour

Ambient – 40

°C to 70 °C with a maximum rate

of change of 20

°C/hour (Thermal shock of

– 40

°C to 70 °C, 10 cycles; transfer time shall

not exceed 5 minutes; duration of exposure to
temperature extremes shall be 20 minutes)

Humidity
(non-
condensing)

To 85% relative humidity

To 95% relative humidity

Altitude

0 to 10,000 feet

0 to 50,000 feet

Reliability

Calculated MTBF of 5 million hours assuming continuous operation at 55

°C, at 200 LFM

airflow nominal input voltage and 80% maximum load

EMI

Complies with the limits of FCC Class B and VDE 243 Level B for radiated emissions

Electrostatic
discharge

15 KV initialization level per specification
number EN61000-3-2. The direct ESD
event shall cause no out-of-regulation
conditions.

(Includes overshoot,

undershoot, and nuisance trips of the
overvoltage protection, overcurrent
protection, or remote shutdown circuitry)

25 KV initialization level






















Advertising